Maintenance
Pointek CLS200/300 requires no maintenance or cleaning.
Instructions specific to hazardous area installations (Reference
European ATEX Directive 94/9/EC, Annex II, 1/0/6)
The following instructions apply to equipment covered by certificate number KEMA
00ATEX2039X and KEMA 00ATEX2040X:
1.
For use and assembly, refer to the main instructions.
2.
The equipment is certified for use as Category 1/2G, 1/2D. Refer to appropriate certificate.
3.
Refer to appropriate certificate for application in specific hazardous environment.
4.
Refer to appropriate certificate for ambient temperature range.
5.
The equipment has not been assessed as a safety related device (as referred to by
Directive 94/9/EC Annex II, clause 1.5).
6.
Installation and inspection of this equipment shall be carried out by suitably trained
personnel in accordance with the applicable code of practice (EN 60079-14 and EN 60079-
17 in Europe).
7.
Repair of this equipment shall be carried out by suitably trained personnel in accordance
with the applicable code of practice (e.g. EN 60079-19 within Europe).
8.
Components to be incorporated into or used as replacements in the equipment shall be
fitted by suitably trained personnel in accordance with the manufacturer's
documentation.
9.
The certificate numbers have an 'X' suffix, which indicates that special conditions for
safe use apply. Those installing or inspecting this equipment must have access to the
certificates
10. If the equipment is likely to come into contact with aggressive substances, then it is the
responsibility of the user to take suitable precautions that prevent it from being adversely
affected, thus ensuring that the type of protection is not compromised.
Aggressive substances: e.g. acidic liquids or gases that may attack metals, or solvents
that may affect polymeric materials.
Suitable precautions: e.g. establishing from the material's data sheet that it is resistant to
specific chemicals.
Please see www.siemens.com/pointek for the latest approval certificates.
Note:
Unit Repair and Excluded Liability
For detailed information, please see the inside back cover.
A5E32221251
Pointek CLS200/300 (Standard) – QUICK START MANUAL
Page EN-15