Franke Maris Water Hub Manual Del Usuario Y De Instalación página 9

Sistema electrónico de agua hirviendo 3 en 1
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 63
Installation
General starting points for installation
Perform the following steps before starting
installation.
1. Stop valves must already be installed.
2. If the water pressure is above the 5 bar, use
a pressure reducing valve (3 bar).
3. Close the stop valves.
4. In existing installations, remove the tap,
hoses and boiler if still in place.
5. Mark the existing cold and hot water
connection.
6. There must be two wall plug sockets
available for connection.
Install the pressure relief valve as high as
possible in the kitchen cabinet.
Operation
Operation of boiler
▶ Briefly pressing the ON/STANDBY button
switches between the boiler modes ON and
STANDBY.
ON: The LED is continousily red.
OFF: The LED is off.
Installation steps
Check the details in the "Installation and user
manual" part 2/2, pages 3-16.
1. Installing 3-in-1 tap (see page 7)
2. Installing filter (see page 8)
3. Installing pressure relief valve (see page 8)
4. Connecting drain hose (see page 9)
5. Installing boiler (see page 9)
6. Installing Hydraulic Box (see page 10)
7. Connecting Hydraulic Box (see page 10)
8. Activating Hydraulic Box (see page 11)
9. Flushing boiler (see page 11)
10. Activating boiler (see page 11)
11. Installing with WWS (see pages 12 and 13)
12. Installing with Bypass (see pages 14 and 15)
13. Commissioning (see page 11)
When the boiler has been switched of for
a week, we recommend that the following
procedure is observed before use:
▶ Switch on boiler. Wait until the boiler water
is up to temperature.
▶ Open the boiling water tap and flush the
boiling water line until cold water comes out
of the tap.
Caution: Ensure that the water does not
atomise during flushing.
▶ Heat the boiler water again.
9
EN