Tap supplies no warm water
Cause
Hose(s) kinked.
Boiler not functioning.
Warm water appliance not
functioning.
The water from the tap is not boiling
Cause
The plug of the boiler has not been
inserted into a wall plug socket.
The wall plug socket has no power
supply.
The boiler is OFF (standby mode).
The boiler has not heated up
completely.
The boiler is defective.
The boiler causes a short-circuit
Cause
There is a short-circuit in the
electric wiring or the heater
element of the boiler.
No water in the boiler. Led is
blinking blue.
If you can't manage your malfunction or defect please contact the Franke service desk, installer or
retailer.
Remedy
Inspect the hose(s) and straighten the kinked hose(s).
See table "The water from the tap is not boiling".
Consult the manual of your warm water appliance, warm water
support or Bypass.
Remedy
Insert the plug into an earthed wall plug socket.
Check the electricity supply.
The electricity circuit has failed due to an excessive load. The
boiler cannot be connected to the same electricity circuit as a
dishwasher.
Switch the boiler ON.
Wait until the boiler has heated up.
Contact Franke.
Remedy
Remove the plug of the boiler from the wall plug socket.
Contact Franke.
Fill the boiler with water.