A2.2 Inactivity
After inactivity open a tap for at least 3-4 minutes to flush all the piping system. This precautionary
operation should always be performed after inactivity of water distribution systems independently
of the presence of water treatment devices.
The term inactivity indicates the absence of withdrawal from any tap (e.g. during holiday).
If the distribution system is subject to cleaning and/or disinfection it is necessary to include the
equipment in the intervention as well.
Cleaning/disinfection is part of the extraordinary maintenance and must be carried
out by an authorized T.A.C..
A2.3 Periodic checks
It is advisable to make two inspections per year by an authorized T.A.C. to verify
proper operation
A2.4 Extraordinary maintenance
If maintenance operations are not carried out correctly, they can compromise the
integrity of the equipment: these operations are deliberately omitted in this manual.
Hence all extraordinary maintenance and repair operations not covered in this manual
should be performed by an Acqua Brevetti Srl authorized T.A.C. To get further
information on T.A.C. please contact Acqua Brevetti Srl (tel.: +39(0)49.8973432, e-

A3 TROUBLESHOOTING

Problem
No consumption of
®
AcquaSIL 2/15

A4 MiniDUE AND DEPLETED REFILL BAGS DISPOSAL

®
The AcquaSIL 2/15
disposable refills are made of plastic multiplayer non recyclable material and
they have to be treated like that. MiniDUE pump is made of plastic non recyclable material and it has
to be disposed according to the current legislation. In case of doubt please contact the waste
management service.

A5 MiniDUE PUMP LABELLING

Check for the SN (Serial Number) that must be reported on the "WARRANTY ACTIVATION" form.
Serial number

A6 EXPLODED

Production date (month/year)
MAN 115
MiniDUE - ENGLISH
.
Cause
No water flow in the pipe
Flow meter impeller blocked.
Pumping chamber sealings are
dry because of the low level of
AcquaSIL in the tank
Incorrect installation of the DIMA
connection (for code PM005)
Pump disconnection for plant
pressure fluctuations
SN XXXX
XXX OY/XY
Solution
Check for the presence of water in
the distribution line by opening a
tap downstream of the pump
Call an authorized T.A.C.
Call an authorized T.A.C.
Call an authorized T.A.C.
Press the bag carefully to facilitate
product riset and eliminate the air
present
PAG.E-8