After opening the water upstream of the equipment check for leaks;
1)
Check for the correct installation of the pump in order to facilitate ordinary maintenance
operations.
2)
Verify the presence of a by-pass circuit that permits the exclusion of the pump and the
presence of sampling faucets upstream and downstream of the pump.
3)
Check the correspondence of the system to any rules or recommendations issued by the
competent local area offices.
4)
Check periodically that AcquaSIL 2/15
the refill bag has to decrease proportionally with water treated). If this is not the case, please
B1.6 Allowed installation schemes
ATTENTION: if you are using the refill in the bag which is remotely located, the dosing pump could
be installed in any position.
Install MiniDUE according to one of the following schemes.
The MiniDUE pumps with ½" connections (code PM004 and PM005) are equipped with bidirectional
connection, the entrance and exit of the water can occur indifferently from both the connections.
The MiniDUE pump with ¾" connection (code PM011) is not equipped with bidirectional connections
thus it has to be installed considering as entrance the side from where three holes are visible (as in
figure).
Any other configuration may lead to the non proper working of the device. Do not over close the
connections.
In case of doubt please contact Acqua Brevetti Srl (Tel.: +39.(0)49.8973432 or send an e-mail
PM004
MAN 115
MiniDUE - ENGLISH
®
is regularly consumed (the amount of product inside
PM004/2
PM004 + AV017
PM005
Wrong installation
PAG.E-11