A2 Instruction For Periodic Maintenance; A3 Troubleshooting - Acqua Brevetti PM010 Manual De Instrucciones Para El Uso Y Mantenimiento

Bomba dosificadora volumétricaelectrónicaproporcional para la dosificaciónde acquasil 20/40
Ocultar thumbs Ver también para PM010:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

A2 INSTRUCTIONS FOR PERIODIC MAINTENANCE
A2.1 Routine maintenance
Perform periodically the following two checks:
®
AcquaSIL 20/40
level check
Check periodically for the level of residual AcquaSIL 20/40
an electronic system for the automatic detection of the liquid level which automatically emits an alarm signal
when the minimum liquid level is attained.
BravaDOS working check
For the proper working of BravaDOS make sure that the product is dosed and consumed regularly. The level
in the storage tank should decrease proportionally with water treated.
BravaDOS refill
Perform periodically the refilling of AcquaSIL 20/40
BravaDOS code PM010: unscrew the storage tank and fill it with AcquaSIL 20/40
indication.
BravaDOS code PM012, PM014, PM016: unscrew the small green cap located in the upper part of the
storage tank and insert the filling funnel; slowly pour AcquaSIL 20/40
®
with AcquaSIL 20/40
up to the maximum level indication.
A2.2 Inactivity
After long inactivity periods open a tap and let water flow for at least 3 minutes. If the water distribution line
should be cleaned and sanitized, BravaDOS should be cleaned and sanitized as well. Cleaning and
sanitization are part of the extraordinary maintenance and must be performed by qualified personnel only.
A2.3 Periodic checks
It is advisable to make two inspections per year by a qualified technician to verify the proper operation of the
equipment and to assess the need of extraordinary maintenance interventions.
A2.4 Extraordinary maintenance
Extraordinary maintenance or repair may affect the proper functioning and/or safety or integrity of the pump:
the description of all these operations are deliberately omitted in this manual. Therefore all extraordinary
maintenance and repair operations are not covered in this manual and should be performed by authorized
personnel only. Acqua Brevetti S.r.l. has created and organized an efficient local technical assistance
extended to the whole country with trained technicians which are available to assist you to ensure the proper
operation of the equipment. In case of problems or if in doubt, please contact Acqua Brevetti S.r.l.

A3 TROUBLESHOOTING

Problem
Green led off
Red led on
Red led on with filled storage tank
Red led off with empty storage tank
No consumption of AcquaSIL 20/40
The green led does not flash even if there is
water withdrawal
The
green led flashes
consumption of ACQUASIL 20/40
MAN 116
BRAVADOS - ENGLISH
®
. Follow the following instructions:
Cause
No power supply
Electronic circuit damaged
Low level alarm
Defective level indicator
Defective level indicator
®
No water flow
Flow meter impeller blocked
Defective injection valve
Flow meter impeller blocked
but
there
is
no
Defective injection valve
®
®
in the storage tank. BravaDOS is equipped with
®
®
from the bottle to the storage tank; fill
Solution
Check the power supply
Replace the electronic circuit
Refill with ACQUASIL 20/40
Call authorized center
Call authorized center
Check for water flow
Call authorized center
Call an authorized center
up to the maximum level
®
PAG.E-5