3
Your Heating System
Product specifi cation
Model name
Modes
Nominal thermal store tank volume
Overall unit dimensions
Weight (empty)
Weight (full)
Primary expansion vessel
Nominal volume
(Accessory item)
Charge pressure
Safety device
Water circuit
Control thermistor (THW1)
(Thermal store tank)
Control thermistor (THW3)
Pressure relief valve (2 No. devices)
Flow sensor
Manual reset thermostat
Booster heater
Manual reset thermostat
Thermal Cut-out
(for dry run prevention)
Primary circuit circulating
Thermal store and space heating
pump
Hot water supply
Connections
Primary circuit
Secondary (potable) circuit
Target temperature range
Space heating
Flow temperature *1
Room temperature
DHW supply maximum temperature
Guaranteed operating
Ambient *2
range
Outdoor temperature
Electrical data
Control board
Power supply
Current
Breaker
(Local supply)
Booster heater
Power supply
Capacity
Current
Breaker
Sound power level
Maximum secondary (potable) water supply pressure
Maximum primary working pressure
Minimum primary working pressure
*1 Depending on the ambient conditions, it may not reach the set temperature.
*2 The cylinder's environment MUST be frost-free.
6
EHPT20Q-VM2EA
Space & DHW heating
200 L
1600 × 595 × 680 mm (Height × Width × Depth)
77 kg
283 kg
18 L or 25 L
1.0 bar (100 kPa)
42 - 72°C
80°C
3.0 bar (300 kPa)
Min. fl ow 1.3 L/min
90°C
90°C
121°C
Grundfos Solar PML 25-145 180
Grundfos Solar PML 25-145 180
ø 22.0
ø 22.0
25 - 60°C
10 - 30°C
40 - 70°C
0 - 35°C (80%RH)
- 15 - 35°C
230V N ~ 50 Hz
(Phase, voltage, frequency)
12.8 A
20 A
230V N ~ 50 Hz
(Phase, voltage, frequency)
2 kW
8.7 A
16 A
40 dB(A)
10 bar (1 MPa)
2.5 bar (250 kPa)
1.0 bar (100 kPa)
4
Customizing Settings for Your Home
To change the settings of your heating system please use the main controller located on the front panel of the cylinder
unit. The following is a guide to viewing the main settings. Should you require more information please contact your
installer or local Mitsubishi Electric dealer.
Main Controller
A
F1
F2
F3
F4
E
B
C
D
11
14 13
10
1
2
9
3
8
7
4
6
5
Main screen
<Main controller parts>
Letter Name
Function
A
Screen
Screen in which all information is displayed.
B
Menu
Access to system settings for initial set up and
modifi cations.
C
Back
Return to previous menu.
D
Confi rm
Used to select or save. (Enter key)
E
Power/Holiday
If system is switched off pressing once will turn
system on. Pressing again when system is
switched on will enable Holiday Mode. Holding the
button down for 3 secs will turn the system off. (*1)
F1-4
Function keys
Used to scroll through menu and adjust settings.
Function is determined by the menu screen visible
on screen A.
*1 When the system is switched off or the power supply is disconnected,
the cylinder unit protection functions (e.g. freeze stat function) will NOT
operate. Please beware that without these safety functions enabled, the
indoor unit and water pipe works may potentially become exposed to
frost damage.
<Main screen icons>
Icon
Description
1
Heat pump
'Heat pump' is running.
Defrosting.
Emergency heating.
2
Electric heater
When this icon is displayed the 'Electric heaters'
(booster heater) are in use.
3
Target
Target fl ow temperature
12
temperature
Target room temperature
Compensation curve
4
OPTION
Pressing the function button below this icon will
display the option screen.
5
+
Increase desired temperature.
6
-
Decrease desired temperature.
7
Z1
Z2
Pressing the function button below this icon
switches between Zone1 and Zone2.
Information
Pressing the function button below this icon displays
the information screen.
8
Space heating
Heating mode
mode
Zone1 or Zone2
9
DHW mode
Domestic hot water heating mode
10
Holiday mode
When this icon is displayed 'Holiday mode'
activated.
11
Timer is activated.
Prohibited
Server control is activated.
Stand-by
Stopped
Operating
12
Current
Current room temperature
temperature
Current water temperature of thermal store
tank
13
The Menu button is locked or the switching of
the operation modes between DHW and Heating
operations are disabled in the Option screen.(*2)
14
SD memory card is inserted. Normal operation.
SD memory card is inserted. Abnormal operation.
*2 To lock or unlock the Menu, press the BACK and CONFIRM keys
simultaneously for 3 seconds.
7