Symptom
BLUE diode does not light (lack of IR
communication)
YELLOW and RED diode light but ra­
diator still cool
BLUE diode lights but radiator
still cool
BLUE diode pulsing
If the problem continues please contact Your local Distributor.
EN
Possible cause
Problem with the connection.
Problem with the heating element
Thermal fuse or electronics
damaged
Room temperature is equal or high­
er than the one set in external
programmer
The heating element is no longer
communicating with the
IR controller
Adviced action
Check the batteries Place the pro­
grammer close to the heating ele­
ment and change the temperature
setting ­ if the devices communi­
cate correctly, LED diode lights blue
and blinks after each order correct­
ly received.
contact the Distributor
contact the Distributor
Everything is working. To make the
heating element heat you may turn
on the ON mode in external pro­
grammer or the Dryer mode in the
element. (Note: Turning the control­
ler 'OFF' will not terminate the con­
nection between the heating ele­
ment and the controller, the only
way to do this is to remove the bat­
teries from the controller or move it
to another room)
Is the controller still in 'line of site'
of the heating element or is it being
blocked by an object or has it been
placed in another room, clear the
obstruction or move the control­
ler. Check the batteries. If not and
the problem still exists ­ contact the
Distributor
17