Anti-freeze function
When the device is off but still has a live feed,
and the temperature inside the room falls
down below 6° C the device will automati
cally turn on and start heating. This function
will prevent the heating medium inside the
radiator from freezing. When this function
is active every 4 seconds a flashing orange
LED diode is visible.
Remote control mode (wireless
communication)
If there is a dedicated IR controller inside
the room, which sends signals to the heat
er, then, the first signal correctly received by
the heater, automatically switches the device
into receiving mode. When in this mode, the
device will heat with the heat output dictat
ed by the external controller while still con
trolling temperature not to exceed approx
imately 60° C. Remote mode is indicated by
the diode shining with constant blue light.
Every correctly received signal from the ex
ternal controller is indicated by short flash
of the diode. If there is a break in communi
cation (the heater does not receive a signal
from the external controller for 30 minutes),
the heater will switch to a signalawaiting
mode. The blue diode will start pulsating
steadily and the device will automatical ly
turn off with the antifreeze function still ac
tive until the connection is reached again.
EN
TIMER function can be used also in remote
mode (in such a case, after the timer oper
ation has seized, the heater will not turn
off but it will return to the remote control
operation).
Malfunction alerts
The device constantly monitors all parame
ters which may indicate its damage or any
adverse phenomena, and automatically acti
vates necessary protective procedures. Those
are, amongst others: protection against op
eration in 'dry conditions', monitoring of con
trolling and measuring systems, monitoring
an 'open window' or 'free flow of water in
a central heating system'. All malfunction
alerts are indicated by a flashing white diode.
15