RedMax EBZ9000 Manual Del Usuario página 14

Idiomas disponibles

Idiomas disponibles

To start the product
1. Set the throttle to the position for idle speed.
EBZ9000
2. Push the start button down fully until it locks in
position.
Note:
If the throttle is not set to idle speed, the
start button does not lock in position.
3. Push the air purge bulb again and again until fuel
starts to fill the air purge bulb. It is not necessary
to fill the air purge bulb fully.
4. Put the product on a flat surface on the ground.
5. Hold the product with the left hand and put one
foot on the foot plate.
Introduction
WARNING:
the safety chapter before you do
maintenance on the product.
Maintenance schedule
Maintenance
Clean the external surfaces.
Make sure that the control handle operates correctly.
14
EBZ9000RH
Maintenance
Read and understand
6. Pull the starter rope handle slowly until
resistance occurs.
7. Pull the starter rope handle quickly with the right
hand until the engine starts.
Note:
Do not pull the starter rope handle to full
extension and do not let go of the starter rope
handle.
8. Let the engine run for 2–3 minutes to become
warm before operation.
To stop the product
CAUTION:
the engine is at idle speed.
Push the stop switch.
EBZ9000
Stop the product when
EBZ9000RH
Daily
Weekly
Monthly
X
X
2318 - 003 - 02.04.2024
loading

Este manual también es adecuado para:

Ebz9000rh970 55 07-01970 55 06-01