With the gate closed permits opening with FT1 obscured
00
does not permit opening
01
permits opening
02
OPENS WHEN IT IS OBSCURED
53 03
Mode if photocell FT2 is interrupted when opening
00
IGNORE, no action or FT2 not installed
01
STOP, the gate remains stationary until the next command
02
REVERSE IMMEDIATELY, thus closing
03
TEMPORARILY STOP, the beam released, it continues to open
04
INVERT WHEN RELEASED, the beam released, it reverses thus closing
54 04
Mode if photocell FT2 is interrupted when closing
00
IGNORE, no action or FT2 not installed
01
STOP, the gate remains stationary until the next command
02
REVERSE IMMEDIATELY, thus closing
03
TEMPORARILY STOP, the beam released, it continues to open
04
INVERT WHEN RELEASED, the beam released, it reverses thus closing
55 01
With the gate closed it permits opening with FT2 obscured
00
does not permit opening
01
permits opening
02
OPENS WHEN IT IS OBSCURED
56 00
With the gate completely open, recloses 6 seconds after photocell interruption
00
OFF (photocell interruption does nothing)
01
the interruption of FT1 causes the closure
02
the interruption of FT2 causes the closure
65 05
Stop space when braking
01
05
1 = quick brake/minimum stopping distance ... 5 = gentle braking
-
70 02
Number of motors
01
1 MOTOR
02
2 MOTORS
NOTE: parameter
72 00
Limit switch enabling
00
no limit switch connected
01
opening limit switch connected
NOTE: parameter
isible only if you set
0-
in simplified mode.
8-
in simplified mode,
A1 03
.
33