Assembly notes
Installation Precautions
1.
The installer must proceed with the installation in strict compliance with the national standard
1.
installation specifications for electric water heaters!
It is strictly forbidden for users to install electric water heaters themselves! When installing, please
2.
contact qualified professionals for the installation of electric water heaters.
When installing the electric water heater, earthing must be absolutely guaranteed! If the installation
3.
conditions for electric water heaters are not met, the installer must clearly inform the user, explain the
reasons and propose solutions. The user must ask professionals to eliminate the security risk before
installation. When risks cannot be corrected, the installation must not take place!
This product must be installed indoors, away from direct sunlight, and the ambient temperature must be
4.
above 0°C; places where there are flammable gas leaks or environments containing highly corrosive
gases must be avoided; places where there is strong electromagnetic interference must be avoided;
places prone to vibration must be attempted to be avoided; the length of the connection between the
water heater and the water intake point must be attempted to be shortened.
Assemble the safety valve during installation! The drain pipe connected to the safety valve's
5.
decompression port must be continuously tilted downwards and remain open to the atmosphere. The
drain pipe and the safety valve must be installed in an environment protected from freezing in order to
avoid any blockage by ice. A well-drained soil drain must be located near the drain pipe in order to
avoid water accumulation.
The method consists of lifting the safety valve handle to see if water flows from the drain pipe. If the
6.
decompression function is normal, the water flows through the drain pipe, otherwise the decompression
is not normal. In the event of abnormal decompression, stop using this product and contact the after-
sales service.
Before installation, check if the wall on which the electric water heater is installed is solid. There must
7.
be no cables buried in the wall. It is strictly forbidden to install the electric water heater on a hollow wall.
The bearing capacity of the wall must not be less than 4 times the mass of the electric water heater
once it is filled with water, and the installation position must guarantee a space of at least 30 cm wide
on the right side of the electric water heater.
The power outlet must be installed in an area not exposed to water and out of the reach of children.
8.
2. Installation steps:
Using a drill, drill holes with a depth of at least 90 mm in the wall. These holes must be level and on the
1.
same line
2. Insert two pegs into the hole, screw the hooks and place them upwards, then lift the electric water
heater and aim for the hooks, secure it in position and check that the pegs are not loose in order to
ensure that the electric water heater is securely fixed.