Technical Data

3.1

Power dependant rating data

Model code explanation
SE 1 1 2 xxxxx
MODEL
AC supply voltage and frequency
Input displacement factor (cos φ)
Nominal motor power - kW
Nominal motor power - hp
Output voltage and frequency
100% RMS output current - A
150% overload current for 60 secs - A
Typical full load input current - A*
Typical inrush current - A** (duration <10ms)
Drive power losses at 230Vac at 6kHz switching
frequency - W
Weight - kg/lb
Cooling fan fitted
* See section 3.1.1.
** For an explanation of inrush current, see section 3.1.2.
MODEL
Recommended input supply fuse - A
Control cable
Recommended input cable
Recommended motor cable
Table 3.2 Recommended supply fuses and cables
Commander SE User Guide
Issue Number 9
Drive kilowatt rating: 00025 = 0.25kW etc.
Drive voltage rating: 2 = 230V, 4 = 400V
Number of input phases: 1 = 1∅, 3 = 3∅, D = 1∅ and 3∅
Frame size.
025
0.25
0.33
1.5
2.3
5.6
Table 3.1 Commander SE Size 1
025
mm²
AWG
mm²
AWG
mm²
AWG
www.controltechniques.com
SE11200...
037
Single phase 200 - 240V +/- 10% 48 - 62Hz
>0.97
0.37
0.50
3 phase, 0 to input voltage, 0 to 1000Hz
2.3
3.5
6.5
100
18
24
1.1/2.4
No
SE11200...
037
6
10
≥ 0.5
20
1.0
16
1.0
16
055
075
0.55
0.75
0.75
1.0
3.1
4.3
4.7
6.5
8.8
11.4
37
56
1.25/2.75
055
075
16
1.5
14
9