Electrolux SANTO 71338-18 DT Manual De Instrucciones página 33

Idiomas disponibles

Idiomas disponibles

Ofrecido por www.electromanuales.com
Electrical connection
Before initial start-up, refer to the appliance rating plate to ascertain if sup-
ply voltage and current values correspond with those of the mains at the
installation location.
e.g.:
AC
220 ... 240 V~
(i.e. 220 to 240 volts alternating current, 50 Hertz)
The rating plate is inside the appliance on the left.
A correctly installed, earthed socket is required for the electrical supply. The
supply must have a fuse rating of at least 10 Amps.
If the socket is not accessible once the appliance is built in, the electrical
installation must include suitable means of isolating the appliance from the
mains (e.g. fuse, cut-out, current trip or similar with a minimum contact
separation of 3 mm).
Attention: The mains connection cable may only be replaced by a skilled
electrician. Please contact your dealer or our customer service department
for repairs.
Prior to Initial Start–Up
• Please clean the appliance interior and all accessories prior to initial start-
up (see section: "Cleaning and Care").
Starting up and temperature regulation
• Insert the plug of the connection lead into the plug socket with protecti-
ve earth contact. When the refrigerator compartment door is opened, the
internal lighting is switched on. The temperature selector knob is located
on the RH side of the refrigerator compartment.
Setting „0" means: Off.
Setting „1" means: Hightest temperature, (warmest setting).
Setting „6" (end-stop) means: Lowest temperature, (coldest setting).
All manuals and user guides at all-guides.com
220 ... 240 V
50 Hz
50 Hz or
33
loading