Hayward AquaRite HC Low Salinity Manual Del Usuario página 22

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25
1
Calibration of free chlorine: It is recommended
unit screen drops below 0.10 ppm (between
to do this once a month during the season the
5 and 60 minutes). Press OK when the value is
pool is in use.
close to 0.
2
5
Calibration using reference values (DPD1
Step 3 of 6 - CL calibration of 2nd point:
photometer): Follow the 6-step instructions that
Open the water intake to a rate of 80-100 litres/h
appear on the display screen (points 4 to 7).
then wait until the free chlorine value is stable
3
Manual calibration: Open the water intake and
(between 5 and 20 minutes). Press OK when the
wait until the free chlorine value displayed on the
value is stable.
6
unit screen is stable. With the up/down buttons,
Step 5 of 6 - With the up/down
adjust the value displayed until it coincides with
the displayed value until it coincides with the
the free chlorine value measured during the
free chlorine concentration measured during the
DPD1 analysis (in ppm), then press OK.
DPD1 analysis (in ppm) then press OK.
4
Step 1 of 6 - CL calibration of 1st point
7
Step 6 of 6 - If this screen does not appear,
(0 ppm): Stop the flow of water through the
repeat the calibration process.
sensor and wait until the value displayed on the
6f. Installing and starting up the free chlorine option (membrane sensor)
Always begin the calibration procedure with a calibration reset.
Please contact your dealer for configuration of the free chlorine sensor equipped with a membrane.
We recommend calibrating the free chlorine sensor with a high chlorine level: between 1ppm and 1.2ppm.
1
Open the cover and connect the CL CHIP card to the CL slot (see section 3C).
The chlorine reading and the Measures menu will be displayed automatically, to
configure the setpoint and carry out the calibration.
2
Configure the 4-20 mA membrane sensor in the service menu.
3
Place the sensor in a bypass, following the sensor instructions.
4
Connect the 3 cables of the floater to the extension circuit board (see section 3C).
5
Connect the 2 cables of the sensor to the extension circuit board (see section 3C).
1
2
3
1
Calibration of the free chlorine sensor equipped with a membrane: It is
recommended to do this once a week during the season the pool is in use.
2
Before beginning the calibration, measure the pool free chlorine (in ppm) by
performing a DPD1 analysis and click on Test DPD1.
6g. Installing the WiFi or Ethernet module
1
Open the cover and connect the WiFi module to the WIFI slot (see section 3C). The Network menu appears automatically in the Settings menu. The power LED remains
steady and the connection LED flashes
1
2
3
1
Internet: Once the module is connected, switch on the device. A Network menu
appears in the Settings menu.
2
Wifi: Select the Wifi menu to start an automatic search for available networks.
3
Choose the relevant available network.
4
Enter the password for this network via the keyboard. To confirm, press OK.
AquaRite
HC LS
®
Only use spare parts supplied by Hayward brands
4
4
.1
.2
5
5
6
.1
.2
buttons,
adjust
6
Leave the sensor to polarise for at least 24h.
7
Start sensor calibration after 24h in operation.
i
The flow through the transparent mount must be constant to ensure optimum
reading.
i
The sensor has a lifetime of 1 year. We recommend calibrating it every month
during the season the pool is in use.
4
ppm Cl2
10
5
0
4
12
3
Step 1 of 3: Enter the value measured during the DPD1 analysis and press OK.
4
Step 3 of 3: Press OK to validate the calibration.
4
5
6
5
Configuration: If you want to configure your connection manually or if automatic
configuration fails, you can change the network parameters in this menu.
6
The default setting "DHCP = ON" must be left as it is.
7
Status: Displays information about your current connection.
Page 18 on 22
®
4
.3
8
9
7
6h. Installing and starting up a variable-speed pump
To install and control a 3-speed pump, please contact your dealer.
H
I
J
K
mA
Diagram of variable-speed pump installation on the AquaRite
20
1
2
3
7
1
2
3
10
11
When the module is connected to the Wifi network and
the two LEDs are continuously on (steady), you can register at
poolwatch.hayward.fr or on the Hayward Poolwatch app.
Get your Node ID (steps
process. You can scan the QR code directly in the app to register
your pool. Once you have registered, you can monitor all your
AquaRite
O nly WiFi networks with a frequency of 2.4 GHz are
accepted by the module.
Thermal circuit breaker / Switch
L
M
red
Pump
HC LS
®
4
5
6
3
Enter the service menu from
the configuration menu.
4
Enter the password (contact
your dealer to obtain the
password).
5
Enter the pump type menu.
6
Select the type of pump.
The default pump type is
"standard" (single-speed).
When using a variable-speed
4
5
6
6
After connecting a variable speed pump, you can assign a
different speed individually to each filtration period, as required.
V1: S, V2: M, V3: F
Filter cleaning: To clean the filter with a variable speed pump, it is
best to use the highest speed (V3).
AquaRite
HC LS
Page 19 on 22
®
Only use spare parts supplied by Hayward brands
®
8
to 11) and follow the registration
®
HC LS parameters remotely with Hayward PoolWatch.
V1
N
V2
O
V3
P
black
Q
Cable must
be added
pump, select variable speed
A, B or
C.
In this case, one
of the 3 default speeds (V1,
V2, V3) can be assigned to
the heating and for when the
cover is closed.
i
Select Var. speed A for a
Hayward variable-speed
pump.
loading