EN
•
Electronic protection against short circuit and overload on the
FLASH, IND/ELEC and LED outputs
•
Protection of 24VAC and PH-POW outputs via resettable fuses
•
Automatic obstacle detection
•
Auto-learning of travel length
TECHNICAL SPECIFICATIONS
Power Supply
Nominal power
Maximum output current 24VAC
PH-POW maximum output current
Maximum FLASH output power
Maximum LED output power
Maximum power for the "IND/ELEC" output
Accessory fuses
Power line fuses
Integrated radio receiver
Antenna
Number of saved transmitters
Can be used in saline, acidic or explosive atmosphere
environments
IP protection class
Overall dimensions
Weight
2.4 - List of cables required
The following table shows the cables necessary for connection of
the various devices in a typical system.
The cables must be suitable for the type of installation; for example,
ELECTRIC CABLE TECHNICAL SPECIFICATIONS
CONNECTION
Control unit power transformer input
Flashing light (FLASH)
Courtesy light (LED)
Antenna
Electric locking (IND/ELEC)
Photocells (transmitter)
Photocells (receiver)
Safety edge
Key switch
Motors power supply (M1 and M2)
Encoder cables
3 - PRELIMINARY CHECKS
Before installing the product, perform the following checks and in-
spections:
check that the gate, the door or the barrier is suitable for automation;
the weight and size of the gate or door and the balance of the barrier
boom must be within the operating limits specified for the automa-
tion system in which the product is installed;
check that the gate or door has firm, effective mechanical safety
stops;
make sure that the product fixing zone is not subject to flooding;
high acidity or salinity or nearby heat sources might cause the pro-
duct to malfunction;
in case of extreme weather conditions (e.g. snow, ice, wide tempe-
rature variations or high temperatures), friction may increase, cau-
sing a corresponding rise in the force needed to operate the system;
the starting torque may therefore exceed that required in normal
6
•
Disabling of unused safety inputs via dip switches: it is not
necessary to insert jumpers on the respective input terminals
(paragraph 4.2)
CT20324
CT20324E
230Vac (+10% - 15%) 50/60 Hz
210W maximum
280W maximum
200 mA (24 VAC)
250 mA (24 VDC non-regulated)
15 W (24 VDC)
15 W (24 VDC)
5 W (24 VDC) / 15 VA (12 VDC)
1.6 AT
433.92 MHz OOK
wire or cable antenna RG58
222 x 110 x 275 H mm
3,87 kg
4,46 kg
we recommend a cable type H03VV-F for installation indoors or
H05RN-F/H07RN-F if installed outdoors.
CABLE
3 x 1,5 mm²
3 x 2,5 mm²
3 x 0.55 mm²
RG58 cable
2 x 1.5 mm²
2 x 0.55 mm²
4 x 0.55 mm²
2 x 0.55 mm²
4 x 0.55 mm²
2 x 1.5 mm²
4 x 0.55 mm²
conditions;
check that when operated by hand the gate, the door or the barrier
moves smoothly without any areas of greater friction or derailment
risk;
check that the gate, door or the barrier is well balanced and will the-
refore remain stationery when released in any position;
check that the electricity supply line to which the product is to be
connected is suitably earthed and protected by an overload and dif-
ferential safety breaker device;
the system power supply line must include a circuit breaker device
with a contact gap allowing complete disconnection in the condi-
tions specified by class III overvoltage;
ensure that all the material used for installation complies with the
relevant regulatory standards.
CT20324L
CT20324EL
115 Vac (+10% - 15%) 50/60 Hz
210W maximum
280W maximum
2.0 AT (timed)
3 AT
150
NO
IP54
3,87 kg
MAXIMUM PERMITTED LIMIT
if less than or equal to 20 m
if greater than 20m, (connect the earth
wire near the control unit)
20m
10 m (recommended < 5 m)
10m
20m
20m
20m
20m
10m
10m
5 AT
4,46 kg