CLEANING AND ADJUSTING SPARK PLUG
(a) If the plug is contaminated with carbon,
using a plug cleaner and wire brush.
(b) Adjust the electrode gap to 0.7 to
0.8 mm (0.028" to 0.031").
SPARK PLUG: CHAMPION RC12YC equivalent.
CLEANING FUEL STRAINER
Dirt and water in the fuel are removed
by the fuel strainer.
(a) Remove the strainer cup and throw
away water and dirt.
(b) Clean the screens and strainer cup
with gasoline.
(c) Tightly fasten the cup to main body,
making sure to avoid fuel leak.
Page 20
SCREEN 1
BODY
SCREEN 2
GASKET
CUP