16 Technical Data
• For dimensions, see the sales catalog TS 2plus, 3 842 531 138.
• Maximum load/section load: 30 kg, 1.0 kg/cm section length
• Noise emissions: < 70 dB (A)
16.1 Ambient conditions
• The transfer systems have been designed for stationary use in a location that
is protected from the elements.
• Operating temperature +5°C to +40°C
• Storage temperature
• Relative humidity
• Air pressure
• Permissible fl oor load: 1000 kg/m
• The load values of the electrical drives are reduced by 15% when the system is set
up in a location with an altitude > 1400 m.
• Avoid molds, fungi, rodents, and other vermin.
• Do not install or operate near industrial systems with chemical emissions.
• Do not install or operate near sandy or dusty sources.
• Do not install or operate in areas that are regularly jarred by high forces caused by
e.g. presses or heavy machinery.
• Resistant to many common media used in production such as water, mineral oil,
grease, and detergents. Contact your Rexroth representative if you have any doubts
about resistance to specifi c chemicals, such as test oil, doped oils, aggressive
detergents, solvents, or brake fl uid.
• Avoid long-term contact with acidic or basic reacting materials.
16.2 Pneumatics
• Oiled or non-oiled, fi ltered, dry compressed air.
• Operating pressure:
• Solids
– Particle size
– Particle quantity
• Humidity – water content
1
– Pressure dew point
)
1
) The pressure dew point should be at least 15°C below the ambient temperature.
• Oil content
– Oil quantity
–5°C to +60°C with 20% reduced load
–25°C to +70°C
5% to 85%, non-condensing
> 84 kPa, appropriate height < 1400 m above sea level
2
4 to 6 bar
≤ 5 µm
(class 6 acc. to ISO 8573-1: 2010)
3
≤ 5 mg/m
(class 6 acc. to ISO 8573-1: 2010)
≤ +3°C
(class 4 acc. to ISO 8573-1: 2010)
3
≤ 1 mg/m
(class 3 acc. to ISO 8573-1: 2010)
3 842 546 879/2015-07, MIT: HQ 2/U, Bosch Rexroth AG
Technical Data
37/38