that the steam exhaust is unobstructed.
Thus, if a permanent hose installed to
an external wall or ceiling, it must be
ensured an exhaust capacity of mini-
mum 150 m3/h. If the dryer is installed
adjacent to kitchen units, make sure
that the vent hose is not squashed. If
the hose is not fully squashed, drying
efficiency will be decreased , resulting
in longer drying times and higher ener-
gy consumption. If the hose is fully
squashed, the automatic cut-outs with
which the appliance is fitted can oper-
ate. When operating the tumble dryer,
the room temperature must not be low-
er than +5°C and higher than +35°C, as
it can affect the performance of the ap-
pliance.
THE LOAD DOOR REVERSAL
WARNING!
Before changing the door stop,
disconnect the mains plug.
1. Open load door.
2. Unscrew hinge A from the front of
the appliance and remove the load
door.
3. Remove cover plates B. To do this,
put a thin screwdriver into the slots
as shown in the illustration, push
down lightly and remove the cover
plates.
A
A
4. Use an applicable tool and apply
pressure to unlock part C, remove
and turn it through 180°, then put
on the other side.
CAUTION!
There is a small spring below
locking block C. To put all parts
together correctly, look at the il-
lustrations:
ENGLISH
25
B
C
B