Moreover, the deflecting roller (13) must be mounted
with the additional hook (fig. 4).
The firmly mounted hook (7) must be suspended at the
mounting hole (8).
The load capacity doubles itself as a result and the
load is now lifted by two steel wire ropes (4). (fig. 5)
9.
Commissioning
Remove the adhesive tape from the wire rope
1.
Check the following functions before getting start-
ed:
2.
Press the push-button (10) upwards, rope is lifted
3.
Press the push-button downwards, rope is lowered
4.
Press the emergency stop switch (9), the rope
hoist comes to a standstill
5.
Release the emergency stop switch (9) (turn clock-
wise), Wire rope hoist is ready to operate.
Make sure that the steel wire rope is rolled up
correctly on the drum and there is no distance be-
tween the turns. (see fig. 6)
6.
Check the limit switch when raising the wire rope
hoist, at maximum height of the automatic stop
lever (6).
7.
Check the limit switch when releasing the wire
rope hoist, at maximum rope length. (Shuts down
automatically)
Pay attention to the fact that the load is secured prop-
erly to the hook or the additional hook.
Ensure that the wire rope is taut when raising the
loads.
Raise the load at the lowest speed.
Always stay at a distance when raising the loads.
Never leave hanging loads unattended.
The motor is equipped with a thermostat switch.
If it comes to a standstill during operation, wait until the
motor has cooled down.
10. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions. The cus-
tomer's mains connection as well as the exten-
sion cable used must also comply with these reg-
ulations.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables of the same designation.
The printing of the type designation on the connection
cable is mandatory.
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
Please provide the following information in the
event of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Engine data - type plate
11. Maintenance plan
ATTENTION! Pull out the mains plug
Clean the rope winch with a rag following use. Keep
the air slits of the motor clean.
After 30 runs (1 run = 1x up and 1x down):
Check the entire steel wire rope (4); in case of dam-
age, replace the steel wire rope according to the spec-
ification (use only original spare parts).