SERVICE RECOMMENDATIONS
MAINTENANCE OPERATION
Every 8 Hours or
25 Hours or Every
SOHours or Every
100 Hours or Every
NOTE 1: Change oil and oil filterafter first 8 hours of operation and then every 50 hours thereafter. Change sooner when operating
under heavy load or in dusty or dirtyenvironmentor in high ambient temperature.
NOTE 2: Clean more often when operatingthe unit under dirty or dusty conditions.
STORAGE
The generator should be started at least once every seven
days and allowed to run at least 30 minutes. If this cannot
be done and you must store the unit for more than 30 days,
use the following information as a guide to prepare it for
storage.
STORAGE
INSTRUCTIONS
WARNING: NEVER STORE ENGINE WITH FUEL IN
THE TANK INDOORS OR IN ENCLOSED, POORLY
,_
VENTILATED
AREAS,
WHERE
FUMES CAN
REACH AN OPEN FLAME SPARK OR PILOT LIGHT
AS ON A FURNACE, WATER HEATER, CLOTHES
DRYER OR OTHER GAS FURNACE.
ENGINE
Run engine for about five minutes to warm it.
NOTE: If you did use =gasohol," drain fuel tank, then run engine
until engine stops from lack of fuel.
WARNING:
DRAIN FUEL INTO APPROVED CON- ]
_
TAINER OUTDOORS, AWAY FROM OPEN FLAME;
I
BE SURE ENGINE IS COOL
J
NOTE:
Using a fuel additive such as Sears Craftsman® Fuel
Stabilizer, or an equivalent, will prevent gum depositsfrom form-
ing in the generator's fuel system.
While engine is still warm, drain oil from crankcase.
Refill with fresh oil.
See BEFORE
STARTING
EN-
GINE on Page 2 for oil recommendations.
Remove spark plug and pour about 1/2 ounce (15ml)
of engine oil into cylinder. Crank slowly to distribute oil
I _
CAUTION:
AVOID SPRAY FROM SPARK PLUG
HOLE WHEN CRANKING ENGINE SLOWLY.
Install spark plug. Do not connect spark plug wire.
Clean dirt, oil and grease from cylinder, cylinder head,
fins, blower housing, rotating screen and muffler area.
Close fuel shut-off valve, located beneath the fuel tank.
GENERATOR
Clean the generator as outlined on Page 5 ("To Clean
the Generator').
Check that cooling air slots and openings on generator
are open and unobstructed.
OTHER
STORAGE
TIPS
Do not store gasoline from one season to another.
Replace your gasoline can if it starts to rust.
Rust
and/or dirt in your gasoline can cause problems when
you use it with this unit.
Store in clean and dry area.
DANGER: STORAGE COVER IS FLAMMABLE. DO
NOT PLACE THE STORAGE COVER OVER A HOT
GENERATOR. LETTHE UNIT COOL FOR A SUFFI-
_k
CIENT TIME BEFORE PLACING THE COVER ON
THE UNIT. IF YOU PLACE THE COVER ON THE
UNIT BEFORE GENERATOR IS COOL, THE COVER
COULD START ON RRE.
12