TECHNICAL DATA SHEET
The Cebilon Platinum reverse osmosis system
meets the NSF/ANSI Standard 58 (US standard
for point of use (POU) reverse osmosis systems
(RO)) for performance standards veri ed with
con rmed test data. Do not use water for this
system that is microbiologically unsafe, that
has not been su ciently disinfected before or
after operation or that is of unknown quality.
TROUBLESHOOTING AND SOLUTIONS
Errors
Possible causes
There are air
bubbles in the water
There is air in the system.
or the water is
colored white.
The pressure pump is not working and there is no
suitable pressure available*.
The pre- lters are clogged.
The system produces
The membrane does not work.
little clean water.
The temperature of the incoming water has dropped.
The check valve is defective.
Although the clean water
The air pressure in the tank is insu cient.
tank is full, no water runs
out of the tap.
A water ow noise can be generated in the
The system generates
waste water tube.
excessive noise.
This may be due to an obstruction or a bent tube.
The pressure switch is defective.
The pump works
The low pressure switch is defective.
constantly.*
The check valve is defective.
The shut-o valve is defective.
The pump is defective.
* Available for the model with pressure pump
Warranty Conditions
This product is manufactured for global distribution and sales.
Since the warranty conditions and periods of this type of product varies from country to
country, please contact your regional distributor or seller for information concerning the
applicable warranty and service policies. Please make sure you understand clearly the
policies and procedures concerning the warranty. It is solely the distributor's responsibili-
ty to set up a warranty policy in compliance with the local laws and regulations.
Cebilon Platinum reverse osmosis system
contains components that need to be
replaced regularly to e ciently
dissolved solids (TDS) from the water. To
check the e ciency of the system, check the
water in the system regularly. Please also
replace the lters according to the speci ed
replacement intervals.
Recommended solution
Air in the system shortly after the rst installation is normal.
Sometimes, there may be air from the water supply. After a
certain operating time, however, this will decrease. The use of
this water is not harmful.
Check if the pressure pump adapter is plugged in. If the adapter
is plugged in, please contact a technician.
Please contact a technician.
Please contact a technician.
This is not a malfunction. It is normal that the amount of fresh
water in winter decreases by a certain amount.
Please contact a technician.
There is not enough air left in the tank.
Please contact a technician.
Correctly align the clamp attached to the siphon and to the
outlet pipe.
Remove the obstruction in the waste water tube or align
the bent tube.
Close the water inlet valve and contact a technician.
Close the water inlet valve and contact a technician.
Please contact our technical support.
Please contact our technical support.
Please contact our technical support.
8
lter the