CHECKS BEFORE THE START-UP
• Insert the plug of the pressure pump adapter
into the 24 VDC power supply input of the
system. Then, connect the adapter to the
power supply.
• Open the tap for the clean water.
• Close the clean water tank valve.
• By opening the 1/4" ball valve, the tap water
is supplied to the system (Fig. 8). The pump
IMPORTANT NOTES
This system has been developed for private
use in households. Components such as the
clean water tank, the waste water tube and
the water tap are not intended for outdoor
installation. Before using the system, carry out
the necessary measures to disinfect microbio-
MAINTENANCE
The maintenance of your system should only
be carried out by an authorized technician.
The service life of the lters used in Cebilon
Platinum reverse osmosis systems changes
with the amount of water treated, depending
RECOMMENDED INTERVALS FOR FILTER REPLACEMENT
To use your system e ciently and for a long
time, carry out the maintenance regularly and
on time. The following replacement intervals
apply to lters that are used under normal
conditions in the water system.
The operating conditions of the lters can
Replacement
Filter Name
interval
5-µm sediment 6 months
Activated carbon
6-12 months
granulate (GAC)
1-µm sediment
6-12 months
Activated
6-12 months
carbon lter
Membrane
2 - 5 Years
For spare parts, please contact your local distributor.
Sediments are ltered by retaining the coarse particles in the water. Thus, the water is ltered down to
the micrometer level. Its service life depends on the quality of the in owing water.
This lter removes the chlorine from the water. Excess chlorine reduces the service life of the upstream
activated carbon granulate lter (GAC). Timely replacement protects against chlorine damage and extends
the service life of the membrane.
This 1-µm sediment lter retains carbon dust to prevent membrane clogging.
This lter regulates the pH value by adding mineralsto the water.
The membrane is where the phenomenon of reverse osmosis occurs. The service life of the membrane changes
depending on the ion concentration in the tap water, the amount of clean water produced and su cient maintenance.
starts working.
• When the water ows, close the tap.
• As soon as pump operation has stopped,
check each individual connection for possible
leaks and open the clean water tank valve.
• Since the tank is being lled for the rst time,
drain the clean water at least once.
logically unsafe water. Install the system with
its own power supply unit. If there is no one in
the house, we recommend that you close the
water inlet valve for safety reasons (Fig. 8).
Repairs have to be carried out by quali ed
personnel.
on several factors. These main factors are: the
quality of the incoming water, the amount of
chlorine, the amount of dry residue, etc. The
lters are considered accessories and are not
covered by the warranty.
change depending on the quality of the
in owing water and the amount of chlorine
and sediments. Only authorized technicians
should perform the periodic maintenance
required to keep your system operating
e ciently every six months.