TECHNICAL SPECIFICATIONS
TANK CAPACITY
8 L (100 psi/689 kPa)
6-7 psi (40-48 kPa)
AIR TANK PRESSURE
34,03 gpd (128,7 L/day)
DAILY CAPACITY
%85-%98
PURIFICATION RATE
30,93%
EFFICIENCY RATIO
34,89%
RECYCLING RATE
0,8 L/dk-1,2 L/dk
PUMP FLOW RATE
PUMP PRESSURE
80 psi-110 psi (551-758 kPa)
24 V DC
POWER SUPPLY PUMP
Diameter: 24.4 cm Height: 36.6 cm
TANK SIZE
450x250x375
DEVICE SIZE (mm)
11,8 kg
TOTAL WEIGHT
OPERATING PRINCIPLE
The rst lter in the system is the 5 µm sediment lter, in which solid particles are retained.
The water then passes through the activated carbon granulate lter (GAC). This lter retains
organic substances and especially free chlorine. Furthermore, odors are eliminated. The
1-µm sediment lter is the last lter before the membrane. This also protects the membrane,
which increases its service life.
The water ltered through the three pre- lters then ows through the membrane, which forms
the basis of the water treatment in the reverse osmosis system. A large number of small particles
are retained here, which are then discharged through the waste water tube.
The water that has been able to penetrate the membrane rst passes through the downstream
activated carbon lter, which has the function of a pH regulator, and then to the clean water tank.
To ensure reliable functioning and a long service life of the membrane, the amount of waste
water must always be bigger than the amount of clean water. The treated clean water in the
tank increases the water supply. The storage capacity of your system is 2.2 gallons, which is
approximately 8 liters.
INSTALLATION
The system is very easy to use and the water pipe system can be easily installed anywhere.
The installation should only be carried out by a quali ed technician.
Cebilon Platinum reverse osmosis system contains components that need to be replaced
regularly to e ciently lter the dissolved solids (TDS) from the water.
Free chlorine can negatively a ect the polymer structure of the membrane within the system.
Do not use water for this system that is
microbiologically unsafe, that has not been
su ciently disinfected before or after
operation or that is of unknown quality.
Cebilon Platinum reverse osmosis system
contains components that need to be
replaced regularly in order to e ciently lter
the dissolved solids (TDS) from the water.
To check the e ciency of the system, check
the water in the system regularly.
Therefore, please also replace regularly the
components that need to be replaced. To
ensure continuous e ciency and performance
of the system, only use components that
meet the de ned speci cations for replacement.
4