Scheppach HPC1600-Kit Traduccion Del Manual De Instrucciones Originale página 27

Limpiador eléctrico de alta presión
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 65
13.2 Cleaning
m WARNING! Do not spray the product with water
or clean it under running water. There is a danger
of electric shock and the product could be dam-
aged.
• Keep protective devices, air vents and the motor
housing as free of dust and dirt as possible. Rub the
product clean with a clean cloth or blow it off with
compressed air at low pressure.
• We recommend that you clean the product directly
after every use.
• Clean the product at regular intervals using a damp
cloth and a little soft soap. Do not use any cleaning
products or solvents; they could attack the plastic
parts of the product. Make sure that no water can
penetrate the interior of the product. Water penetra-
tion increases the risk of an electric shock.
You can remove foreign objects from clogged nozzles
with the nozzle cleaning needle (26).
Rinse the nozzles with water to remove foreign objects.
14. Storage (Fig. 3)
• Store the product and its accessories in a dark, dry
and frost-free place that is inaccessible to children.
• Wind the mains cable (4) onto the holder for the
mains connection cable (2).
• Stow the accessories on the accessories mounting
bracket (7) and the high-pressure hose (18) on the
high-pressure hose mounting bracket (8).
• The optimum storage temperature is between 5 and
30˚C.
• Store the product in its original packaging.
• Cover the product to protect it from dust or moisture.
• Store the operating manual with the product.
15. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions. The cus-
tomer's mains connection as well as the exten-
sion cable used must also comply with these reg-
ulations.
Important information
In the event of overloading, the motor will switch itself
off. After a cool-down period (time varies) the motor
can be switched back on again.
Damaged electrical connection cable.
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables of the same designation.
The printing of the type designation on the connection
cable is mandatory.
AC motor:
• The mains voltage must be 220 - 240 V~.
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm².
Connection type Y
If it is necessary to replace the mains connection ca-
ble, this must be done by the manufacturer or their rep-
resentative to avoid safety hazards.
16. Repair & ordering spare parts
After repairs or maintenance, make sure that all safe-
ty-related parts are installed and are in perfect con-
dition. All parts which may cause injury must be kept
where they are inaccessible to children or others.
Attention: According to the German Product Liability
Act, no liability is accepted for damage caused by im-
proper repairs or by not using original spare parts.
Such work should be performed by a customer service
centre or an authorised specialist. The same applies to
accessory parts.
www.scheppach.com
GB | 27
loading

Este manual también es adecuado para:

5907737901