3. TECHNICAL DATA
Model
ECL250
Mains voltage /
220-240V
frequency
50 Hz
Power consumption
250 Watts
Max. flow rate
8 000 l/h
Total pressure head Max.
6 m
Depth of immersion Max.
7 m
Water temperature Max.
35 ºC
Power cable
H05RNF - 10 m
Protection Class
IPX8
Weight
3,9 kg
Dimensions (mm)
270x170x170
Outlet connection
F 33/42 (1"1/4)
Size of solid particles
5 mm
pumped Max.
4. AUTOMATIC MODE
1. The pump switches on when the rising wa-
ter reaches the sensor
The pump starts then stops to carry out de-
gassing then starts pumping . Metal contacts
at the bottom of the sensor strip detect the
minimum water level(switch-off point).When
the minimum water level is reached, the
pump stops after a delay.
2. Fit the sensor onto the sensor strip in the
desired switch-on position.
5. MANUAL MODE
The pump is switched on when the sensor is
ECL400
inserted in the top-most position of the sen-
sor strip.
220-240V
The pump is then in forced operation and will
50 Hz
only stop when the user has unplugged it
400 Watts
This manual mode therefore requires extreme
12 000 l/h
vigilance but allows the pump to reach the
maximum drying level.
8 m
Metal contacts at the bottom of the sensor
7 m
strip detect the minimum water level(deacti-
35 ºC
vation point) .When the minimum water level
is reached, the pump switches off with a brief
H05RNF - 10 m
delay.
IPX8
Repeat the process: reinsert the sensor in the
3,9 kg
top position of the sensor strip.
280x170x170 mm
F 33/42 (1"1/4)
5 mm
6. INSTALLING THE PUMP
1. Install the pump on a horizontal, stable sur-
face in the water.
2. If it needs to be lowered into a well or a
shaft, fasten a rope to the handle.
Do not carry it by the power connection cable.
3.Install the pump such that it does not take in
dirt particle with a size > 35mm, which would
block the intake. Install the pump in a raised
position if necessary. for example on a brick.
7. OPERATION WARNING
1.Only Operate the pump if no persons are
in water
2.Disconnect all electrical devise in the water
from the power supply before reach into the
water.
Risk of severe injuries or death by
electric shock
GB