HR Matic HR B120+ Manual De Instalación página 33

Idiomas disponibles

Idiomas disponibles

11- DIP SWITCH
The B120+ control unit includes a 4-way dip switch with which some operating parameters can be changed.
NOTE: only when the control unit is installed, each time the DIPs are
changed, a message relating to the changed function will appear on the
display.
DIP
POSITION
1 OFF
2 OFF
1 ON
2 OFF
1 OFF
2 ON
1 ON
2 ON
3 OFF
3 ON
4 OFF
4 ON
12- OPEN GATE LIGHT SIGNALLING (SCA)
INDICATOR LIGHT
SLOW FLASHING
ALWAYS ON
QUICK FLASHING
13- LAMP SIGNALLING (FLASHING LIGHT)
FLASHING LIGHT
ON/INTERMITTENT (*)
QUICK FLASHING
(*) The continuous power supply (for flashing light) or intermittent power supply (to transform normal lamps into indicators) is
determined by the parameter BASIC MENU -> LAMP OUTPUT.
FUNCTION
Step-by-Step (PP)
command
(or radio control)
Inversion push
LAMP forewarn
OFF
2 FLASHES
OFF
OPEN-CLOSE: each time the PP command (or radio control) is
pressed, the action is performed according to the sequence indicated
above.
REMOTE OPENING: the PP command (or radio control) triggers an
opening movement. A closing command con only be made when the
gate is fully open.
OPEN-STP-CLOSE-STP: each time the PP command (or radio
control) is pressed, the action is performed according to the
sequence indicated above.
CONDOMINIUM: via the PP command (or radio control), or closure
of the TMR contact (external clock), an opening movement is
performed.
Only when the gate is fully open does closure start automatically after
the pause time has elapsed or the TMR contact opening has been
triggered.
DISABLED
ENABLED: at each opening, only when the gate is completely
closed, a short closure is performed to facilitate release of the electric
lock.
DISABLED: the indicator lights up at the same time as the start of
the manoeuvre.
ENABLED: the indicator lights up 2.5s before the manoeuvre.
Gate closed
Gate in motion
Gate stationary open
Installation necessary or unknown position
Alarm situation warning
Gate stationary
Gate in motion
Installation necessary or unknown position
14
DESCRIPTION
DESCRIPTION
DESCRIPTION