6- CONNECTION TERMINALS
TERMINAL
12,13
43,44
42,41
LEGEND
(NC) Input normally closed, to be short-circuited with 0V power output if not used
(NO) Input normally open, must be left open if not used
NOTE: the AUX1 input assumes the opening safety function (SA). If no opening safety
is used, close the input to ground (0V) with a jumper.
CODE
1,3
F - N
Power supply 230Vac ± 10% (50-60Hz)
-
Ground connection
LAMP
4,5
Flashing light output 230VAC
11
CH
M2 motor close output (beaten door)
10
COM
M2 motor common output (beaten door)
9
AP
M2 motor open output (beaten door)
8
CH
M1 motor close output (hinged door)
7
COM
M1 motor common output (hinged door)
6
AP
M1 motor open output (hinged door)
LC
Courtesy light output 230Vac
21
ES
Electric lock output 12Vac
22
0V
Power reference output 0V
24
24V
Power supply output +24Vdc
25
SCA
Open gate light output 24Vdc
26
PP
Step-by-step control input (NO)
27
STP
Stop command input (NC)
30
APP
Pedestrian opening command input (NO)
31
FOT1
External photocell 1 input (NC)
34
FOT2
Internal photocell 2 input (NC)
35
SC
Sensitive edge (NC o 8K2)
36
0V
Power reference output 0V
32
TMR
External clock input (NO)
46
AUX1
Safety input on opening
47
0V
Power reference output 0V
48
CK
Photocells check power supply output +24Vdc
CH2
Second radio channel output
ANT
Antenna connection
BLE
Bluetooth module connector
FC-EN
Limit switch module connector
RADIO
Radio module
DESCRIPTION
6