This section will help you solve any problems you may encounter.
For each of the most commun problems, you will find below a table explaining the possible causes of the
malfunction and the solutions to resolve it.
1. Pump does not start.
Possible causes
Air inlet
No water in the pump
Valves closed
Hydraulic system blocked
Reverse the input/output
connection
2. The flow rate is low.
Possible causes
Dirty filter
Skimmer and/or pump
pre-filter blocked
Air inlet
Valves closed or hydraulic
system blocked
3. Engine gets hot.
It is normal for the motor to get hot as long as it can be touched. Thermal protection will activate stopping the
pump if the temperature is excessive.
Possible causes
Very low or incorrect voltage
Installation in full sunlight
4. Motor does not work.
Possible causes
No power supply
5. Pump is noisy.
Possible causes
Defective parts
Suction lock
Cavitation
T
ROUBLESHOOTING
1 / Make sure that the water level is correct at the suction point.
2 / Fasten all clamps and fittings on the suction side of the pump.
Fill the pump prefilter with water then slightly unscrew the T-plug on the
pressure gauge to release air.
Open all system valves.
Check that nothing is blocking the pump impeller.
Clean the skimmer and prefilter baskets.
Check that the water inlet hose (skimmer) is connected to the pump (and the
return connected to the tank).
Clean the filter balls. See "Cleaning of filter balls", page 31.
Check that nothing is blocking the pump impeller.
Clean the skimmer and pump baskets.
Make sure that the water level is correct at the suction point.
Open all system valves. Clean the skimmer and pre-filter baskets.
The power supply must be corrected by an electrician.
Protection from the sun.
1 / Check that all electrical connectors are connected.
2 / Check that the socket to switch the pump is connected has a good power supply.
3 / Make sure that the circuit breakers are correctly installed.
Replace the entire pump.
Check that nothing is blocking the turbine (gravel, sand, leaves, etc.).
Locate and remove the blockage.
1 / Improve suction.
2 / Reduce the height of the water column in the suction.
3 / Reduce the number of connections.
4 / Increase the diameter of the pipelines.
Solutions
Solutions
Solutions
Solutions
Solutions
EN | 31