Order No.
CCBPWN1350D8
CCBPWN2000D8
8.4
Ambient conditions
Features
Operation site
Working temperature
Storage temperature
Type of cooling
Relative humidity
Working height
Degree of protection as per DIN EN60529 (IEC60 529)
Protection class as per DIN EN 61140 (VDE 0140-1)
9
Troubleshooting
Problem
Tool does not start.
Tool not recognized.
Tool doesn't start with counter-
clockwise rotation activated.
Tool shuts off prematurely.
Apex Tool Group
Sound Level
Free Speed
ISO 15744
[dB(A)]
<70
<70
Data
Indoors
0 °C – 40 °C
-25 °C – 65 °C
Convection (self-cooling)
10 % – 90 %, no condensation
Up to 3000 m (9,843 ft) above sea level
IP40
II
Possible cause
No speed programmed.
Controller is waiting for tool en-
ablement.
Fast-Apps mode disabled.
Self-identification data are not
recognized after tool change.
Software is incorrect.
FastApps mode is activated.
Tool is defective.
With counterclockwise rotation,
parameter for speed is set to
1
0
/min.
Operator releases start trigger
before the controller stops the
tool.
The fastening time exceeds
the standard time of 10 sec-
onds.
P2506BA | REV D l 2023-10
Sound Level
Vibration Level
Uncertainty
No Load
ISO 28927-2
[m/s²]
±3
±3
Measure
► Check Linking group. In the mPro mode, se-
lect Navigator> Standard or Navigator> Basic.
► Check FastApps. In the FastApps mode:
>
.
► Enable the input Tool Enable or, if not re-
quired, deactivate Tool Enable.
► Enable FastApps mode:
Accept Tool Settings again:
1.
Navigator > Tool Setup.
2.
Select the line with the tool.
3.
Select Tool Settings> Accept.
► Check controller and measuring card soft-
ware.
► Disable FastApps mode to connect to the
controller.
► Change tool.
Parameterize Speed left rotation
► Select on the controller Navigator > Stand-
ard > Tool Groups > Settings For Speed Left
Rotation.
► Make sure that the operator keeps the start
trigger pressed throughout the entire se-
quence.
► Increase the fastening time.
Vibration
Level
Uncer-
tainty
<2,5
1,5
<2,5
1,5
>
>
.
13
1
EN