Cleco CellCore CCBPWN Serie Manual De Instrucciones página 10

Herramienta ec sin cable
Idiomas disponibles
  • ES

Idiomas disponibles

1
EN
Display
Default settings:
White
Green
Tool running
OK rundown
Work Light
Default settings:
Blue
Green
Tool running
OK rundown
5.1
Reaction Bar
These tools require a reaction bar! Reaction forces are
contained by the reaction bar, so forces are not passed
back to the operator.
5.2
Additional Handle
For more controllable use of the hand-held tool.
Warning
Crushing
Unexpected tool movement due to reaction
forces, breakage of drive square or reaction
bar may cause injuries. There is a risk of
crushing between the reaction bar and work
piece.
► Keep hands away from reaction bar and
tool output.
► Keep hands away from additional han-
dle.
If necessary, attach a balancer to the additional handle.
6
Before Initial Operation
Charging Battery Pack
Battery pack is supplied partly charged and must be
charged completely being used for the first time.
► See Original Instructions of Milwaukee charger.
► Do not use any other battery packs / chargers than
the following:
Battery pack 18 V
Order no.
Capacity
T50-1000497
2,0 Ah
T50-1000498
5,0 Ah
Charger 18 V
Order no.
Country
T50-1000499
North America
T50-1000506
Europe
T50-1000507
Brazil
T50-1000543
Argentina
T50-1000544
United Kingdom
10
Order no.
T50-1000545
T50-1000546
Red
T50-1000500
NOK rundown
T50-1000508
T50-1000547
Working with controller (mPro-Modus)
Red
► Configure the tool, refer to the Programming Manual
NOK rundown
tool.
► Configure WLAN on the controller, refer to the Quick
Installation Guide and the Programming Manual
mPro(...)GCD.
Stand-alone (FastApp-Modus)
► Configure the tool, refer to the Programming Manual –
Cordless Assembly Tool – High Torque.
6.1
In operation, the reaction bar rotates in the opposite direc-
tion to the Output Square Drive and must be allowed to
rest squarely against a solid object or surface adjacent to
the bolt to be tightened. React should be on the end of the
reaction bar. When loosening attach the reaction bar on
the opposite side.
Fig. 1-2: Reaction moment
The supplied reaction bar has been designed to give an
ideal reaction point when used with a standard length
socket. In order to take into account a small difference in
the socket length, the reaction recording can have contact
at any point, in the shaded area of the illustration see Fig.
1-3: Safe Support Window, page 11.
1-Bay
P2506BA | REV D l 2023-10
Country
China
Japan
North America
Europe
United Kingdom
Use Reaction Bar
6-Bay
Apex Tool Group
loading