Initial Operation - Astralpool EVOTOP INVERBOOST 05 Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 147

5.4 Initial operation

After all connections, have been made and checked, carry out the following procedure:
1. Switch on the filter pump, check for leaks and verify that water is flowing from and to the swimming pool.
2. Connect power to the heat pump and press the On/Off button
start up after the time delay expires (see below).
3. After a few minutes, check whether the air blowing out of the unit is cooler.
4. When turn off the filter pump, the unit should also turn off automatically, if not, then adjust the flow switch.
Depending on the initial temperature of the water in the swimming pool and the air temperature, it may take several
days to heat the water to the desired temperature. A good swimming pool cover can dramatically reduce the required
length of time.
NOTE
Water Flow Switch:
It is equipped with a flow switch for protecting the HP unit running with adequate water flow rate. It will turn
on when the pool pump runs and shut it off when the pump shuts off.
Time delay - The heat pump has a built-in 3-minute start-up delay to protect the circuitry and avoid excessive
contact wear. The unit will restart automatically after this time delay expires. Even a brief power interruption will
trigger this time delay and prevent the unit from restarting immediately. Additional power interruptions during this
delay period do not affect the 3-minute duration of the delay.
5.
5.
5.
Location
Location
Location
and
and
and
- 20 -
connection
connection
connection
on the LED control panel. The unit will