Initial Operation - Astralpool PRO-ELYO INVERTER 13 Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 169
NOTE
The factory supplies only the heat pump. All other components, including a bypass if necessary,
must be provided by the user or the installer.
ATTENTION:
In order to heat the water in the pool (or hot tub), the filter pump must be running
to cause the water to circulate through the heat pump. The heat pump will not
start up if the water is not circulating.

4.4 Initial operation

After all connections have been made and checked, carry out the following procedure:
1. Switch on the filter pump, check for leaks and verify that water is flowing from and to the swimming
pool.
2. Connect power to the heat pump and press the On/Off button
unit will start up after the time delay expires (see below).
3. After a few minutes, check whether the air blowing out of the unit is cooler.
4. When turn off the filter pump, the unit should also turn off automatically, if not, then adjust the flow
switch.
5. Allow the heat pump and the filter pump to run 24 hours a day until the above 1 degree than desired
water temperature is reached. The heat pump will stop running at this point. After this, it will restart
automatically (as long as the filter pump is running) whenever the swimming pool water temperature
drops 1 degree below the set temperature.
Depending on the initial temperature of the water in the swimming pool and the air temperature, it may take
several days to heat the water to the desired temperature. A good swimming pool cover can dramatically
reduce the required length of time.
9
on the LED control panel. The
Tabla de contenido
loading

Este manual también es adecuado para:

Pro-elyo inverter 21Pro-elyo inverter 35

Tabla de contenido