4. USE OF PRODUCT
4.1 uSe of GaS burnerS
Ignition of the burners
The position symbol above each control
knob indicates the burner that the knob
controls.
Manual Ignition of the Gas Burners
If your appliance is not equipped with an
ignition aid, or in case there is a failure in
the electric network, follow the procedures
listed below.
For Hob Burners: Push in the knob of
the burner you wish to ignite and keep
it pressed while turning it anti-clockwise
until the knob is in the 'maximum' position.
Continue pressing the knob and hold a lit
match, taper or other manual aid to the
upper circumference of the burner. Move
the ignition source away from the burner as
soon as you see a stable flame.
For Oven Burner: Push in and turn the
oven control knob anti-clockwise until the
knob is in the 'maximum' position. Hold a
lit match, taper or other manual aid to to
the ignition hole that is located on the front
left corner of the burner. Move the ignition
source away as soon as you see a stable
flame.
For Grill Burner: Push in and turn the grill
control knob clockwise until the marker on
the knob points at the grill sign. Continue
pressing the knob and hold a lit match,
taper or other manual aid to the holes on
the burner. Move the ignition source away
from the burner as soon as you see a stable
flame.
Flame safety device
Hob burners
Hobs equipped with a flame failure device
provide security in case of an accidentally
extinguished flame. For this reason, during
ignition, keep the knob pressed until you
see stable flames.
Hold down the control for approximately
10 to 15 seconds after the burner has
lit. Releasing the control too soon will
extinguish the flame.
If such a case occurs, the device will block
the burners gas lines and will avoid any
accumulation of unburned gas. Wait 90
seconds before re-igniting an extinguished
gas burner.
Oven / Grill (If available) Burners
Regardless of the model of your appliance,
all oven burners are equipped with a gas
safety device. For this reason, during
ignition, keep the oven knob pressed until
you see stable flames.
Hold down the control for approximately
10 to 15 seconds after the burner has
lit. Releasing the control too soon will
extinguish the flame.
If the flames are cut out after you release
the knob, repeat the ignition procedure.
If the oven burner does not ignite after
you keep the burner knob pressed for 30
seconds, open the oven door and do not
attempt re-ignition for at least 90 seconds. If
the oven flames go out accidentally, repeat
the same procedure.
4.2 hob ControlS
Hob burner
The knob has 3 positions: off (0), maximum
(big flame symbol) and minimum (small
flame symbol). Ignite the burner with the
knob in the 'maximum' position; you can
then adjust the flame length between the
'maximum' and 'minimum' positions. Do
not operate the burners when the knob is
between the 'maximum' and 'off' positions.
OFF position
MIN. position
After ignition, visually check the flames.
If you see a yellow tip, lifted or unstable
flame, switch the gas flow off, then check
the assembly of burner caps and crowns
once they have cooled. Make sure there is
no liquid in the burner caps. If the burner
flames go out accidentally, switch the
burners off, ventilate the kitchen with fresh
air and wait at least 90 seconds before
attempting re-ignition.
EN - 20
MAX position
MODULATE