SUNFEEL CO592PRO Manual De Usuario página 48

Idiomas disponibles

Idiomas disponibles

supply and that the gas feed is open. The
minimum flame position is adjusted with a
flat screw located on the valve. As shown
in the figures; for valves with a flame failure
safety device, the screw is located on the
side of the valve spindle and for valves
without a flame failure safety device, the
screw is located inside the valve spindle. To
make adjusting the flame position easier,
we recommend that you remove the control
panel (and the micro switch if your model
has one) during the alteration. The bypass
screw must be loosened for conversion
from LPG to natural gas. For conversion
from natural gas to LPG, the bypass screw
must be tightened.
Valve with flame failure
device
Bypass screw
Determining the minimum flame position
To determine the minimum position, ignite
the burners and leave them on in the
minimum position. Remove the knobs
because the screws are accessible only
when the knobs are removed. With the help
of a small screwdriver, fasten or loosen the
bypass screw by around 90 degrees. When
the flame has a length of at least 4mm,
the gas is well distributed. Make sure that
the flame does not die out when passing
from the maximum position to the minimum
position. Create an artificial wind with your
hand towards the flame to see if the flames
are stable. For the oven burner, operate the
oven burner at the minimum position for 5
minutes, then open and close the oven door
2-3 times to check the flame stability of the
burner.
Valve without flame
failure device
Screw(inside the hole)
Bypass screw
Non-thermostatic
oven valve
Bypass screw
Changing the gas inlet
For some countries, the gas inlet type
can be different for NG/LPG gases. In
this case, remove the current connection
components and nuts (if any) and connect
the new gas supply accordingly. In all
conditions, all components used in gas
connections should be approved by local
and/or international authorities. In all gas
connections, refer to the "Assembly of
gas supply and leakage check" clause
explained above.
2.5 eleCtriCal ConneCtion
anD Safety (if available)
WARNING: The electrical connection
of this appliance should be carried out
by an authorised service person or qualified
electrician, according to the instructions in
this guide and in compliance with the
current local regulations.
WARNING: THE APPLIANCE MUST
BE EARTHED.
Before connecting the appliance to the
power supply, the voltage rating of the
appliance (stamped on the appliance
identification plate) must be checked for
correspondence to the available mains
supply voltage, and the mains electric
wiring should be capable of handling the
appliance's power rating (also indicated
on the identification plate).
During installation, please ensure
that isolated cables are used. An
incorrect connection could damage
your appliance. If the mains cable is
damaged and needs to be replaced this
should be done by a qualified person.
EN - 16
Thermostatic oven valve
loading