8. TROUBLESHOOTING
Problem
Engine does not start.
Unusual noises
Strong vibrations
Compressor switches on
frequently.
Compressor runs without
interruption / compressor
does not reach cut-off
pressure.
Air leak from pressure
switch valve with
compressor off
ATTENTION: Do not make any modifications to the machine that may damage its operation. Any
alterations or modifications made will invalidate the product warranty.
If your device continues to give errors or presents any other type of problem, please contact our
technical service so that our team can advise you and solve the problem.
32
Possible cause
No or too low voltage.
Outdoor temperature too low.
Device is not switched on.
Extension cable is too long or too thin.
Pneumatic connectors are loose.
Pneumatic connectors are loose.
Compressor is overloaded.
Too much condensation in the
pressure vessel
LAir consumption for connected
pneumatic tools and devices is too
high.
Quick couplings leaking.
Pneumatic connectors leaking.
VCheck the valve that, due to wear or
dirt on the gasket, does not perform its
function correctly.
Solution
Make sure that the plug is inserted into
the socket.
Check the fuse and replace it if
necessary.
Check the mains voltage.
Ensure +5 °C ambient temperature.
Press the on/off switch to position "I", to
switch on the compressor.
Replace the extension cable (min. 1.5
mm², max. 5 m long).
Check all connecting parts and tighten
them carefully if necessary.
Servicing and maintaining the
compressor.
Observe the manufacturer's
instructions for your tool or equipment,
especially with regard to the amount of
compressed air required.
Empty the pressure vessel regularly.
Comply with the manufacturer's
instructions for your pneumatic tool,
especially with regard to the amount of
compressed air required.
Check quick coupling , replace if
necessary.
Check pneumatic hose and tools,
replace if necessary.
Unscrew check valve hex head, clean
valve seat and rubber gasket (replace
if worn). Reassemble and carefully
tighten (Fig 15 y 16).