MODELS 18753-0335, 43670-0004
SECONDARY
REMOTE CONTROL KITS
5", 7" & 8" CHROME SEARCHLIGHTS
146 SL and 255 SL SEARCHLIGHTS
43670-0004 (12 Volt) or 18753-0335
(24 Volt)
INSTALLATION INSTRUCTIONS
1. Mount searchlight and control per product
data sheet.
2. Mount station selector panel near the
primary control. (Flybridge or lower)
3. Cut a 2" x 1-3/8" (51mm x 35mm) opening
for the station selector panel within a 1
foot radius of the control.
4. Route secondary control cable from sta-
tion selector panel to secondary control
location. (Cable acquired separately)
5. Insert station selector panel thru mount-
ing hole and attach connectors to mating
connectors from controls and searchlight.
The connector marked "flybridge" to go
to the flybridge control and the connector
marked "lower" to go to the lower control.
The connector to the nearest control can
be plugged directly into the control. See
diagram on reverse side.
6. Use bedding compound or sealant to wa-
terproof station selector panel mounting.
7. Secure panel with self tapping screws
provided.
8. Mount secondary control per instructions.
XYLEM LIMITED WARRANTY WARRANTS THIS PRODUCT TO BE FREE OF DEFECTS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR. THE WARRANTY IS EXCLUSIVE
AND IN LIEU OF ANY AND ALL OTHER EXPRESS OR IMPLIED WARRANTIES, GUARANTEES, CONDITIONS OR TERMS OF WHATEVER NATURE RELATING TO THE GOODS
PROVIDED HEREUNDER, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WHICH ARE
HEREBY EXPRESSLY DISCLAIMED AND EXCLUDED. EXCEPT AS OTHERWISE PROVIDED BY LAW, BUYER'S EXCLUSIVE REMEDY AND SELLER'S AGGREGATE LIABILITY FOR
BREACH OF ANY OF THE FOREGOING WARRANTIES ARE LIMITED TO REPAIRING OR REPLACING THE PRODUCT AND SHALL IN ALL CASES BE LIMITED TO THE AMOUNT
PAID BY THE BUYER HEREUNDER. IN NO EVENT IS SELLER LIABLE FOR ANY OTHER FORM OF DAMAGES, WHETHER DIRECT, INDIRECT, LIQUIDATED, INCIDENTAL,
CONSEQUENTIAL, PUNITIVE, EXEMPLARY OR SPECIAL DAMAGES, INCLUDING BUT NOT LIMITED TO LOSS OF PROFIT, LOSS OF ANTICIPATED SAVINGS OR REVENUE,
LOSS OF INCOME, LOSS OF BUSINESS, LOSS OF PRODUCTION, LOSS OF OPPORTUNITY OR LOSS OF REPUTATION. THIS WARRANTY IS ONLY A REPRESENTATION OF THE
COMPLETE LIMITED WARRANTY. FOR A DETAILED EXPLANATION, PLEASE VISIT US AT WWW.XYLEM.COM/EN-US/SUPPORT/, CALL OUR OFFICE NUMBER LISTED, OR
WRITE A LETTER TO YOUR REGIONAL OFFICE.
Wiring diagrams on next page.
2
SECONDARY
CONTROL MOUNTING
43670-0004 (12 Volt) or
18753-0335 (24 Volt)
Mount secondary control in same manner as
main control. Mount station selector panel
near the main control (flybridge or lower).
1. Cut a 2" x 1-3/8" (51mm x 35mm) open-
ing for station selector panel within a 1
foot radius of the control.
2. Route secondary control cable from sta-
tion selector panel to secondary control
location (cable acquired separately – see
cable listing).
43990-0013 10ft (3m)
43990-0014 15ft (4.5m)
43990-0015 25ft (7.6m)
43990-0016 35ft (10.7m)
3. Insert station selector panel thru mount-
ing hole and attach connectors to mating
connectors from control and searchlight.
The connector marked "flybridge" to go
to the flybridge control and the connector
marked "lower" to go to the lower control.
The connector to the nearest control can
be plugged directly into the control. See
diagram on reverse side.
4. Use bedding compound or sealant to wa-
terproof station selector panel mounting.
5. Secure panel with self-tapping screws
provided.