Argo DELUXE 9000 UI Manual De Instalacion Y Uso página 52

Idiomas disponibles

Idiomas disponibles

AFTER INSTALLATION CHECK
1. The screws whether have been fixed effectively, and there is no risk of loosening.
2. Connector of display board whether put in the right place and do not touch the terminal board.
3. Control box cover whether cover tightly.
INSTALLATION OF OUTDOOR UNIT
DIMENSION DRAWING OF OUTDOOR UNIT INSTALLATION
Left installation feet
Air inlet
Air outlet
REFRIGERATING CONNECTIONS
Use equipment and connecting pipes suitable for R32 refrigerator.
MODELS
Min. - Max. pipe lenght with gas standard
charge (m)
Max. pipe lenght with gas additional charge (m)
Additional refrigerant charge (g/m)
Max. height between units (outdoor on top) (m)
Max. height between units (indoor on top) (m)
Always write the additional refrigerant charge on the data label affixed to the unit outside.
V 11/23
Space to the obstruction
Space to the obstruction
Air out side
W1
W2
Right installation feet
A
Air in side
Installation outdoor unit bolt
Outdoor unit size oh shape
W1(W2)*H*D (mm)
665(710)x420x280
600(710)x500x240
730(780)x545x285
709(761)x536x280
750(804)x550x285
800(860)x545x315
785(845)x555x300
825(880)x655x310
900(950)x700x360
970(1044)x805x395
940(1010)x1320x370
940(1008)x1366x401
650(703)x455x233
9000
12000
3 - 7
3 - 7
20
20
15
15
10
10
10
10
Space to the
obstruction
A (mm)
B (mm)
430
280
500
260
540
280
480
283
480
283
545
315
546
316
540
335
632
352
675
410
625
364
610
388
480
253
18000
24000
3 - 7
3 - 7
25
25
25
25
15
15
15
15
52
loading