Argo DELUXE 9000 UI Manual De Instalacion Y Uso página 50

Idiomas disponibles

Idiomas disponibles

DIMENSION DRAWING OF INDOOR UNIT INSTALLATION
20 cm above
MOUNTING PLATE
1. The wall for installation of the indoor unit shall be hard and firm, so as to
prevent vibration.
2. Use the "+" type screw to fasten the peg board, horizontally mount the peg
board on the wall, and ensure the lateral horizontal and longitudinal vertical.
3. Pull the peg board by hand after the installation, to confirm whether it is solid.
WALL-THROUGH HOLE
1. Make a hole with an electric hammer or a water drill at the predetermined
position on the wall for piping, which shall slant outwardly by 5°-10°.
2. To protect the piping and the cables from being damaged running through
the wall, and from the rodents that may inhabit in the hollow wall, a pipe
protecting ring shall be installed and sealed with putty.
Note: usually, the wall hole is Ø60 mm ~ Ø80 mm. Avoid pre-buried power wire
and hard wall when making the hole.
ROUTE OF PIPELINE
Depending on the position of the unit, the piping may be routed sideway from the left or the right (Fig 1), or vertically
from the back (Fig 2) (depending on the pipe length of the indoor unit).
DRAIN PIPE CONNECTION
1. Remove the fixed part to pull out pipe of indoor machine from the case.
Screw the hexagon nut in the left of the joint to the end with your hand.
2. Connect the connecting pipe to the indoor unit: Aim at the pipe center,
tighten the Taper nut with fingers, and then tighten the Taper nut with a
torque wrench, and the direction is shown in diagram on the right. The
torque used is shown in the following table.
V 11/23
INSTALLATION OF INDOOR UNIT
Space to the ceiling
Space to
the wall
Space to the floor
Connecting
pipe drain hose
and cables
Outlet material
Fig.1
preparation
15 cm above
Space to the
wall
20 cm above
200 cm above
Fig.2
Indoor unit pipe
Spanner
Pipe
protection
ring
Putty
Connecting
pipe drain hose
and cables
Taper nut Connecting pipe
Torque
wrench
50