semble the wheels (II) with screws to the right and left side of the compressor base, use washers on the inside and screw on the
nuts. Screw with a suitable spanner. Ensure that the components are securely fastened.
The product with the catalogue number YT-23320 must be fi tted with a handle. Use a spanner to loosen the fi xing screws. Place
the handle in the bracket. Tighten the screws with a spanner. Check that the handle does not move during operation.
Installing the air fi lter (III)
It is essential to install an air fi lter in the products with the catalogue numbers YT-23300 and YT-23305 before fi rst use. Remove
the air fi lter plug. Screw the air fi lter clockwise by hand into the air fi lter opening.
Setting the compressor
Place the compressor on a level, fl at, and stable surface away from fl ammable substances in a well-ventilated room protecting the
device from the weather. The compressor should be placed approximately 2.5 metres away from walls and objects.
Checking the oil level/topping up the oil
CAUTION! Remove the blanking plug fi tted for transport and screw in the oil plug (IV). Check the oil level on the indicator (V)
before starting work. If necessary, top up the oil so that the level is in the centre of the sight glass. If the oil level is too low (below
the bottom of the sight glass), there is a risk of the pump seizing. An oil level that is too high (top of the sight glass) or the use of
the wrong type of oil poses the risk of oil entering the pneumatic system with the air.
Use an air compressor oil with a viscosity of SAE 15W40 for the compressor.
Change the factory oil after 10 hours of the compressor operation. The procedure for changing oil is described further in this
instructions manual.
Connecting the compressor to the power supply
Ensure that the compressor power switch is in the off position (press the power switch down). Plug the compressor into a mains
socket.
Compressor operation
Connect the hoses with the connected pneumatic tools that will be used for the work to the quick connectors. Ensure that the
power switch of the devices is in the off position.
Turning the compressor on/off (VI)
To turn on the compressor, set the power switch to the on position (pull the power switch up). The compressor will start by fi lling
the tank to the factory set pressure shown in the technical data table. During operation, the amount of air consumed depends
on the type of tools used. The device operates in automatic mode, maintaining the factory set tank pressure level. To turn off the
compressor, set the power switch to the off position (press the power switch down).
Adjusting the operating pressure
Do not exceed the maximum pressure specifi ed in the specifi cations of the connected tools and hoses. The permissible value
should be checked in the tool manufacturer's technical specifi cations.
Use the pressure regulator (VII) to set the appropriate output pressure. The compressor is equipped with two pressure gauges.
The value of the set output pressure can be read on the pressure gauge located under the regulator. The tank pressure can be
read on the pressure gauge located under the compressor power switch (VI).
Overload protection (VIII)
Products with the catalogue numbers YT-23310 and YT-23320 have an electric motor overload protection system. The overload
protection activates at high motor temperatures. In the event of a safety device tripping, the device will turn off automatically.
Allow the device to cool down. To turn the device back on, turn off the compressor by pressing the power switch down. Press the
overload switch. Turn on the compressor by pulling the power switch up.
MAINTENANCE
CAUTION! Allow the device to cool down completely before carrying out maintenance activities. Turn off the compressor using the
power switch and then disconnect the power cord plug from the mains socket.
Remove air and condensate from the tank as described further in the instructions manual – "Draining condensate from the tank".
This should be done thoroughly and after each use of the compressor. Otherwise, the water can lead to rusting of the tank, which
will damage it. Precipitation of water from the air is a natural phenomenon associated with temperature changes. Therefore, emp-
tying the tank of air should not be neglected. The compressor tank is not weldable or repairable. If the tank is found to be damaged,
contact the manufacturer's authorised service centre; do not turn on a damaged compressor.
Clean the device housing with a cloth slightly dampened with water and dry it. Clean the surroundings of the air inlet and outlet with
a compressed air jet with a pressure of no more than 0.3 MPa. Ventilation openings can also be cleaned with a paint brush or a
brush with soft plastic bristles. Do not use alcohol, solvents, acids or corrosive agents for cleaning. After cleaning and performing