VONROC CR505DC Traducción Del Manual Original página 10

Ocultar thumbs Ver también para CR505DC:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 37
EN
1. Open the connection valves (14) on both sides
of the air pressure hose (15), so the clamping
levers (23) will be in position as shown on figure
D1.
2. Put one of the open connection valves onto the air
pressure outlet connector (22) on the machine,
as shown on figure F. Now close the valve by
pushing the clamping lever (24) downwards.
3. Mount the other open connection valve (14)
onto the valve of the inflatable (if necessary,
first remove valve cover of the inflatable). Now
also close this valve by pushing the clamping
lever (24) downwards, as shown on figure G.
Connecting the valve with valve adapter
(Fig. A, B, C, D, F)
Take care not to over-inflate footballs, they
might burst.
Given the material composition of inflatable
mattresses, inflatable boats etc., the air
pressure cannot be indicated exactly. Take
care therefore not to over-inflate such items
or they might burst.
1. Open the connection valves (14) on both sides
of the air pressure hose (15), so the clamping
levers (23) will be in position as shown on figure
D1.
2. Put one of the open connection valves onto the air
pressure outlet connector (22) on the machine,
as shown on figure F. Now close the valve by
pushing the clamping lever (24) downwards.
3. Push the respective valve adapter (5-10) into
the opening of the other open connection valve
(14). Now also close this valve by pushing the
clamping lever (24) downwards.
4. Insert the valve adapter (5-10) into the valve on
the inflatable (if necessary, first remove valve
cover of the inflatable).
Switching the machine on/off (Fig. A, C)
• Press the on/off switch (21) and the machine
will turn on.
• To turn the machine off, again press the on/off
switch (21).
Note: the machine will switch off automatically
after about 10 minutes to save battery life.
10
Changing the Unit of Measurement (Fig. A, E)
For the pressure indicator, the units bar and psi
are available. To change the unit of measurement,
short press the unit change button (29) until the
required unit of measurement appears in the
measuring unit indicator (28).
Inflation (Fig. A, E)
WARNING: Risk of Bursting. Excessive air
pressure may cause a hazardous risk of
bursting or personal injury. Check the
manufacturer's maximum pressure rating
for items being inflated.
Follow the steps as described in the relevant
chapter above, depending if an adapter is required
or not.
Inflation with user defined target pressure
1. Press the reduce target pressure button (31) or
increase target pressure button (30) as many
times as needed until the required value is set
on the display (27).
2. After the required value is set, the display (27)
will return the current pressure value.
3. Press the start/stop button (32) to start the
inflation process. The pressure shown on the
display will now increase to the set pressure.
4. The inflation process will stop automatically as
soon as the set target pressure is reached. It is
always possible to manually stop the inflation
process by pressing the start/stop button (32).
Inflation with Car/SUV preset target pressure
The device is fitted with two preset target pressure
options: Car-2.40 bar and SUV-2.80 bar. Please
note that these are only indicative values.
Actual tire pressure varies from vehicle to vehicle.
We therefore strongly recommend that you consult
your vehicle manual to find out the recommended
tire pressure.
1. Press either the car preset button (25) or the
SUB preset button (26). The preset pressure will
be shown on the display (27).
2. After the required value is set, the display (27)
will return the current pressure value.
3. Press the start/stop button (32) to start the
inflation process. The pressure shown on the
display will now increase to the set pressure.
4. The inflation process will stop automatically as
soon as the set target pressure is reached. It is
WWW.VONROC.COM