Install
Venti(ation
It is strongly recommended to install a hood above this range. For
most kitchens with a wall mounted hood, a certified hood rating
of not less than 350 CFH is recommended. Bosch hoods rated at
350 CFH or more when operated
on high meet the above
requirement and are recommended for this purpose. The range
hood must be installed according to instructions furnished with
the hood.
2o Prepare
Cabinets
(See
Figure
1)
This unit can be installed near adjacent walls and projecting
surfaces constructed of combustible materials. There must be
a minimum clearance of 30 inches between the top of the
cooking surface and the bottom of an unprotected wood or
metal cabinet; or 24 inches when bottom of wood or metal
cabinet is protected by not less than !/4" of flame retardant
material covered with not less than No. 28 MSG sheet metal,
0.015 inch stainless steel or 0.024 inch aluminum or copper.
Zero clearance from unit walls to adjacent vertical combustible
wails is permitted on rear, right and left walls. Clearance from
range top to adjacent vertical wails must be at least 4". Seal
any, openings in the wall behind the appliance and in the floor
below the appliance.
For the cabinets over the cooking surface and the adjacent cabinets,
the maximum cabinet depth from back wall is !3 inches.
The gas su pply line a nd electrical outlet must be within the spaces
indicated in Figure 2. The gas shut offvalve must also be accessible
without moving the range.
Instructions
were determined using Standard American base
cabinets measuring 36" high x 24" deep. If nonstandard cabinets
are used, care should be taken to alter dimensions accordingly.
NOTICE: Some cabinet finishes cannot survive the temperatures
allowed by U.L., particularly self-cleaning ovens; the cabinets may
discolor or stain. This is most noticeable with laminated cabinets.
3, Instal( Anti°Tip Bracket
!.
Adjust height of range and level by rotating the
adjustable leg supports on the bottom of the range,
using !-1/4"
wrench.
2.
Measure to locate bracket position as shown in Figure 3.
3.
Secure bracket with 2 screws adequate for mounting
surface, not included. (i.e.; for wood floor use wood screws
for
concrete
floor
use concrete
anchors
and screws,),
Q
30"
Minimum
Centerec
!
30'
Min.
I B
_
No Clearance
to Cabinet/
Im
Wall
Required
O
18'
4"Min.
ure 1: Cabinet Preparation
P(ace Gas Supply
Line and
Electrical
Outlet
Here
Figure 2: Gas Supply Line and Electrical Outlet Placement
Figure 3
Backwall
Cabinet Sidewall
Flush
\
Anti-Tip Device
Page 3