Mondial Framec J-X-TOP-TANGO Instrucciones De Uso Y Manutención página 6

Idiomas disponibles

Idiomas disponibles

INSPECTIONS AND
MAINTENANCE
EVERY DAY
Check the operating temperature inside the tank through the thermometers T
l
(Picture 2-3-4)
The cabinet is equipped with automatic defrost: make sure the finned evaporator
l
E (Picture 7) is not clogged by ice.
Check the ventilation of the refrigerating units: the compressor housing grids on
l
the bottom of the cabinet must not be clogged (eg.: boxes, paper).
EVERY MONTH
Clean the cabinet (as described at INSTALLA TION) after having unplugged it and
l
removed the ice cream bins.
The inside part intended for the ice cream storage must be carefully cleaned
l
avoiding the use of cleansers or products no compatible with foods.
In order to make easier the drain of the water accumulated in the reserve bay,
l
remove D plug (Picture 7) taking care to place it again at the end of the operation.
Make sure the finned condensers (visible through the compressor housing grids)
l
are not clogged (eg.: fluff, dust).
For an excellent running of the cabinet and to save energy, it is very important the
finned condensers are clean: the cleaning is to be carried out by skilled technical
staff, who will proceed as follows:
CLEANING OF THE CONDENSER: (Picture 9)
1 Unplug the cabinet.
2 Remove the compressor housing protection grids.
3 Clean the condenser with a brush, an air jet or a vacuum cleaner in order to avoid
damaging the cabinet.
4 Reassemble the protection grids through the special fastening screws.
5 Plug the cabinet in.
EVERY TWO YEARS
Get the cabinet checked by skilled technical staff to make sure:
l
- The inside components of the compressor housing are clean.
- The electric system of the cabinet is not cut-off
- The cabinet works properly (Thermic performance).
It is advisable to get a written declaration about the good working order of the cabinet.
The replacement of the feeding cable must be carried out by skilled technical staff,
l
using cable with indissoluble plug and a minimum wire section of 3 x 1,5 mm 2 .
The wiring diagram is supplied in a special envelope and must be carefully kept
l
together with this handbook and the certificate of guarantee.
In TOP/E and J models the wiring diagram is placed inside the electric plant space.
l
If the cabinet shows working problems, it is advisable to check if:
l
- The plug is well connected with the socket and the electric energy is on.
- The thermostat knob is not in the STOP position or on minimum.
After these inspections, if the problem persists, ask to the Service Center for assistance.
loading