Service
Overhaul and preventive maintenance is recommended at regular intervals once
per year or after maximum 250.000 tightening depending on which occurs
sooner. More frequent overhaul may be needed if the machine is used in heavy-
duty operations. If the machine not is working properly, it should immediately
be taken away for inspection.
When dismantling the tool always use the specially designed service tool 4080
0848 80, (two service tools are required).
Lubrication
Planetary gears, needle bearings and ball bearings must be lubricated with soft
grease containing molybdenumdisulphide at the regular overhaul of the tool.
Lubrication
Lubricate specially gears and clutch with grease containing molybdenum disul-
phide (e.g. Molykote BR2 Plus). Please see exploded views. Lubricate o-rings
and threaded connections with grease before assembling.
Lubricating guide
Brand
Molycote
CRC
Brand
Molycote
Almagard
Repair
Repair
Repair must only be carried out by qualified authorised personnel. For further
information contact your local Atlas Copco sales representative.