GENERAL WARNING

This hood has been developed and produced in accordance with DS/
EN 60335-1.
This hood is intended for home use only. Using for other purposes
will make the warranty invalid.
All installations must be carried out by a qualified technician in ac-
cordance with the instructions set out by Thermex Scandinavia A/S
(Thermex) and the Laws in force.
Thermex disclaims any liability for damage resulting from improper
installation, assembly, operation or incorrect settings.
BEFORE INSTALLATION/OPERATION
Check the hood for transport damage, defects and missing parts
immediately upon receipt.
Transport damage should be reported immediately to the transport
company and Thermex upon receipt.
Any defects and/or missing parts should be reported to Thermex
within 8 days of receipt and prior to installation/operation.
INSTALLATION
The hood is designed to operate at 230 volts ± 10% ~ 50 Hz in ac-
cordance with EN 50160
Connect the hood with the attached plug. NOTE: If the plug has an
Earth terminal, the hood MUST be earthed.
For models with an external motor it is important NOT to use com-
mon zero when installing the hood and motor, as this will affect
operation.
When using an external motor from another supplier, the motor
MUST be compatible with the selected hood. Failure to comply with
this will invalidate the warranty.
The hood must not be connected to the mains before installation is
complete.
The air must not be discharged from the hood into a pipe used for
extraction from devices using gas or other combustible materials.
Such devices must have a separate vent.
The national law and building regulations etc. for air emissions
must be observed.
Always use the original exhaust measurements. Reduction of the
exhaust size will reduce performance and increase sound levels.
The exhaust from the hood to the outside should be as short as
possible in order to maximise the efficiency of the hood.
The number of bends on the exhaust should be minimal in order to
maximise the efficiency of the hood.
Thermex recommends that vent hoses insulated against noise and
condensation for all bushings in unheated rooms are always used.
Thermex recommends using a silencer when flexible hoses are used
in order to minimise sound levels.
When using flexible hoses, always ensure that they have been fully
extended in order to minimise air resistance and thereby maximise
suction performance.
Different materials require different rawlplugs and screws. Rawl-
plugs and screws suitable for the material onto which the hood will
be mounted on must be used.
If the instructions for the installation of screws and fittings are not
followed, it may result in electrical shock.
The minimum distance to gas hobs from the burner's edge to the
underside of the hood MUST be a minimum of 65 cm in accordance
with EN 60335-2-31.
For cupboard-integrated, suspended and wall-mounted hoods,
Thermex recommends that the distance between the hob and cook-
er hood is between 50 cm and 70 cm in order to ensure maximum
suction.
Always check the minimum distance between the hob and the
cooker hood, as indicated in the instructions for the hob. The in-
structions for the hob MUST be observed if a greater distance than
that recommended by Thermex is indicated in this manual.
Thermex recommends that the distance between the hob and the
hood should not exceed 3 metres for ceiling-integrated models.

USE OF THE HOOD

Always read this manual carefully BEFORE using the hood.
Always keep this manual for future reference.
Always disconnect the power to the hood prior to cleaning, mainte-
nance or repair.
Do not repair or replace any part of the hood, unless specifically rec-
ommended in the instruction manual.
A qualified technician must carry out all repairs.
The hood may only be used by children under 8 years of age, people
with physical, mental or sensory disabilities and persons who lack
experience or knowledge if these persons are supervised or have
received the necessary training in the safe use of the product.
Children should be supervised so that they do not play with the
hood.
Children may only carry out cleaning and maintenance when under
supervision.
The hood must be cleaned regularly to ensure optimal operation
and long service life.
Grease and dust debris collect in the filter and may risk igniting with
insufficient cleaning.
The hood should be cleaned inside and out frequently to avoid
grease stains on walls or other surfaces.
If the hood is used together with appliances that use gas or other
combustible material, there must be adequate ventilation.
NEVER flambé beneath the hood.