TABLE OF ROUTINE MAINTENANCE TO BE PER-
FORMED BY THE USER
Description of operations:
Check power cable - pipes - high pres-
sure connectors
Ist oil change in H.P. pump
Subsequent changes in H.P. pump
Change and clean fuel filters
Clean fuel tank
Clean water filter
For water cleaners without
oil drain bung, contact our
technical service centre for
replacement.
Use only SAE 15W 40 oil.
!
Warning
Oil e may cause environmen-
tal pollution. Always follow the
instructions given on the pack.
(Dispose of carefully.)
CLEANING THE FUEL
FILTER AND TANK.
Remove and replace the in-
line fuel filter (fig. 15).
Change it from time to time.
Empty the fuel tank.
Open the drain cap (fig. 16) (if
available) and let any impuri-
ties drain out into a container.
Flush out the tank with clean
fuel and close the drain cap.
CLEANING THE WATER
FILTER
Clean the water intake filter
regularly and free it from any
impurities (fig. 17).
CHANGING THE NOZZLE
The high pressure nozzle
fitted on the lance must be
changed from time to time,
as this component is subject
to normal wear during use.
Wear may generally be de-
tected by a drop in the working
pressure of the cleaner. To re-
place it, consult your supplier
and/or dealer for instructions.
Each use
Every 500 hours
Every 500 hours
Every 250 hours
Every 250 hours
Every 250 hours
English
TABLE OF EXTRAORDINARY MAINTENANCE TO
BE PERFORMED BY THE TECHNICAL SERVICE
CENTRE
Description of operations:
Boiler:
Clean Coil
Descale coil
Clean fuel pump
Change fuel nozzle
Regulade electrodes
Change electrodes
Change seals on H.P. pump
Change lanze nozzle
Calibrate and check the safety devices
DESCALING
Descaling must be carried out from time to time because the
scale present in the water partially deposits inside the hydraulic
circuit and the coil which with time becomes clogged.
Apply to our technical service centre to have the machine des-
caled from time to time; this will save you money and increase
the efficiency of the cleaner.
26
Every 250 hours
Every 500 hours
Every 250 hours
Every 250 hours
Every 250 hours
Every 500 hours
Every 500 hours
Every 200 hours
Every 500 hours