Kärcher HD 4.5/32-4 S Eb Manual Del Usuario página 12

Ocultar thumbs Ver también para HD 4.5/32-4 S Eb:
Idiomas disponibles

Idiomas disponibles

Operating Instructions
As and when required
Emptying and cleaning the detergent
tank
– Pull out the screw cap and hose for the
detergent tank.
– Place the unit on its rear.
– Empty and clean the detergent tank.
Troubleshooting
Danger!
!
Before any repair work is undertak-
en, switch the unit off and pull out the power
plug. Have electrical components checked
and repaired only by authorised Customer
Service personnel.
For faults which are not identified in this
chapter, or when in doubt or when express-
ly instructed to do so, consult authorised
Customer Service personnel.
Indicator light
The indicator light shows the operating sta-
tus (green) and faults (red).
To reset:
Switch off the unit switch.
Wait a moment.
Switch the unit back on again.
Operating status display
Constant green light:
– Unit is operational.
1 x flashing green:
– Operational readiness expired after
30 minutes.
– The unit switched off after 30 minutes of
permanent operation (safety feature in
the case of a burst high-pressure hose).
12
All manuals and user guides at all-guides.com
Fault display
Unit does not work
Unit does not come up to pres-
sure
1 x flashing red:
– High-pressure side leaking. Check high-
pressure hose, hose connections and
hand-held spray gun for leaks.
2 x flashing red:
– Motor too hot. Switch off the unit switch.
Leave unit to cool down. Switch the unit
back on again.
3 x flashing red:
– Fault in the power supply. Check the
mains connection. Check supply fuses.
4 x flashing red:
– Current consumption too high. Consult
Customer Service
Availability time has run out. The indica-
tor light will flash green. Switch the unit
off and then on again.
Check connecting cable for damage.
Consult Customer Service if there is an
electrical fault.
Set nozzle to "high pressure".
Clean/replace nozzle.
Clean the fine filter, replace if required.
Evacuate air from the cleaner (see
Switching on the unit).
Check water inlet volume (see Technical
Specifications).
Check all supply lines to the pump for
leaks or obstructions.
Seek the help of Customer Service if
necessary.
English
loading

Este manual también es adecuado para:

Hd 4.5/32-4 s ec