Beta 599DGT-A/20 Instrucciones página 22

Ocultar thumbs Ver también para 599DGT-A/20:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 62
ANGLE READOUT MODE OPERATION
80% of target angle reached
NB:
1. Hold the torque wrench fast, in the horizontal position, when the "angle mode" is entered.
2. After a few seconds the "angle mode" will start and will blink.
3. When the "angle mode" is entered, press "up" or "down" to set the target torque and angle values.
4. When the wrench is released, in the "angle mode", the display will show the corresponding torque value
with blinking LEDs.
5. When 80% of the target value is reached, the green LEDs will start blinking, and an intermittent sound
will be heard.
6. When 99.5% of the set value is reached, a continuous sound will be heard, and the green LEDs will stop
blinking and will remain on, together with the red LEDs.
7. Press "M" to record the reached angle value.
22
Start
Press
Flashing
Wait 1 second
* Note 3
Automatic switch
Set target angle
Apply as much as needed to reach target torque and rotate
Release force
Automatic switch
Current angle
* Notes 4,7
Apply as much as needed to reach target torque and rotate.
80% of target angle reached
Target angle reached
Release force
Automatic
Current angle
((...((...
* Note 1
* Note 2
Set torque
Current torque
((...((...
...)) ...))
* Note 5
Current torque
switch
...)) ...))
* Note 6
loading