Metabo HPT NT 1850DG Manual página 16

Idiomas disponibles

Idiomas disponibles

English
Lights ;
The battery remaining power is over 75%.
Lights ;
The battery remaining power is 50%–75%.
Lights ;
The battery remaining power is 25%–50%.
Lights ;
The battery remaining power is less than
25%.
Blinks ;
The battery remaining power is nearly
empty. Recharge the battery soonest
possible.
Blinks ;
Output suspended due to high temperature.
Remove the battery from the tool and allow it
to fully cool down.
Blinks ;
Output suspended due to failure or
malfunction. The problem may be the battery
so please contact your dealer.
As the remaining battery indicator shows somewhat
differently depending on ambient temperature and battery
characteristics, read it as a reference.
CAUTION
Do not give a strong shock to the display panel
or break it. It may lead to a trouble.
TESTING THE NAILER
DANGER
Operators and others in work area MUST wear
safety glasses with side shields which conforms
to ANSI Z87.1 specifications.
16
Table 6
WARNING
● Make sure the trigger is locked when not firing
nails.
This Nailer has a lock mechanism to prevent the
nails from being fired.
Set the lock lever at the
trigger.
Slide the lock lever to the
Nailer is to be used, and to the
it is not in use.
Trigger
Lock lever
● Never use Nailer unless push lever is operating
properly.
Before actually beginning the nailing work, test the Nailer
by using the checklist below. Conduct the tests in the
following order.
If abnormal operation occurs, stop using the Nailer and
contact a metabo HPT authorized service center
immediately.
1. REMOVE ALL NAILS AND BATTERY FROM
NAILER.
ALL SCREWS MUST BE TIGHTENED.
THE PUSH LEVER AND TRIGGER MUST MOVE
SMOOTHLY.
Trigger
Push lever
position to lock the
position when the
position when
Lock position
Free position
loading