► 1. Pneumatic tool oil
When an air set is not used, oil the tool with pneumatic
tool oil by placing 2 (two) or 3 (three) drops into the air
fitting. This should be done before and after use. For
proper lubrication, the tool must be fired a couple of
times after pneumatic tool oil is introduced.
FUNCTIONAL
DESCRIPTION
CAUTION:
•
Always disconnect the air hose before adjusting
or checking function on the tool.
Adjusting the nailing depth of
nailing
CAUTION:
•
Always disconnect the hose before adjusting the
depth of nailing.
► 1. Adjuster
1
1
A B
1
► 1. Too deep 2. Flush 3. Too shallow
If nails are driven too deep, turn the adjuster clock-
wise. If nails are driven too shallow, turn the adjuster
counterclockwise.
The adjustable range is 6 mm (1/4"). (One full turn
allows 1.0 mm (1/32") adjustment.)
Use the nose adapter
CAUTION:
•
Always disconnect the hose before installing or
removing the nose adapter.
1
► 1. Protrusion 2. Hole 3. Nose adapter
If you like to protect the surface of workpiece, attach the
nose adapter of contact element.
When nailing workpieces with easily-marred surfaces,
use the nose adapter. To attach the nose adapter to the
contact element, press it onto the contact element until
the protrusion in three places inside the nose adapter fit
in three holes in the contact element.
ASSEMBLY
CAUTION:
•
Always disconnect the air hose before loading
the nailer.
5 ENGLISH
2
3
2
3